Chemical Resistances of Braided Sleeving

To Braided Sleeving

Grades Solvents Weak Bases Salts Strong Bases
Aromatic Aliphatic Chlorinated
Insultherm 1 1 1 1 1 1
PET Standard 2 1 3 1 1 2
Heavy Wall 2 1 3 1 1 2
Flame Retardant 2 1 3 1 1 2
Halar® 1 1 1 1 1 1
Fray Resistant 2 1 3 1 1 2
Fray Resistant(FR) 2 1 3 1 1 2
PET Wrap 2 1 3 1 1 2
PET Wrap(FR) 2 1 3 1 1 2
Flexo Super Duty 1 1 1 1 1 2
Teflon® 1 1 1 1 1 1
Ryton®   1   1 1  
Nylon® 1 1 1 1 1 2
Nylon Multifilament 1 1 1 1 1 2
Carbon Fiber            
Fiberglass   1   1 1  
Reflex*            
Mylar*            
Nomex - - - - - 1
Non-Skid - - - - - -
Kevlar 2 2 2 1 1 2
Thermashield - - - - - -
Insultherm Header Wrap n/a n/a n/a n/a n/a n/a
Insultherm Spark Plug Boot Insulators - 1 - 1 1 -
Dura-Flex Professional 1 1 1 1 1 2
Test Method
Standard
1=No Effect  2=Little Effect  3=Affected  4=More Affected  5=Severely Affected

 

Grades Salt Water Hydraulic Fluid Lube Oil De-lce Fluid Strong Acids Strong Oxidants Esters Keytones UV Light Petroleum Fungus
Insultherm 1 1 1 1 2 2 1 2 1 1
PET Standard 1 1 1 1 3 2 1 1 1 1
Heavy Wall 1 1 1 1 3 2 2 1 1 1
Flame Retardant 1 1 1 1 3 2 2 1 1 1
Halar® 1 1 1 1 1 1 2 1 1 1
Fray Resistant 1 1 1 1 3 2 1 1 1 1
Fray Resistant(FR) 1 1 1 1 3 2 2 1 1 1
FireFlex Aerospace and Industrial Fire Resistant Fiberglass Cable Sleeves 1 1 1 1 - - - 1 1 -
PET Wrap 1 1 1 1 3 2 2 1 1 1
PET Wrap(FR) 1 1 1 1 3 2 2 1 1 1
Flexo Super Duty 1 1 1 1 5 5 1 2 3 2
Teflon® 1 1 1 1 1 1 2 1 1 1
Ryton® 1 1 1 1     1 1 1 1
Nylon® 1 1 1 1 5 5     3 2
Nylon Multifilament 1 1 1 1 5 5 1 2 2 3
Carbon Fiber                    
Fiberglass 1 1 1 1   2 1 2 1 1
Reflex*                    
Mylar*                    
Kevlar 1 1 1 1 2 2 1 4 1 2
Nomex - - - - 2 2 - 3 1  
Non-Skid - 1 1 1 - - - - 1  
Thermashield 1 1 1 1 - - - 1 1  
Insultherm Header Wrap n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a
Insultherm Spark Plug Boot Insulators 1 1 1 1 - 2 1 2 1  
Dura-Flex Professional 1 1 1 1 5 5 1 2 3 2
Test Method
Standard
O-S-1926 MIL-H-5606 MIL-L-7808 MIL-A-8243           ASTM G-21*

 

* Customer must test for application suitability

Grades Automotive Aviation Marine A/V Wire & Cable Industrial Robotics Military Racing Computers
PET Standard *   * * * * * * * *
Heavy Wall     * * * * * * *  
Flame Retardant   *   * *   * * * *
Halar®   *   * *     * * *
Fray Resistant *   * * * *   * * *
Fray Resistant(FR)   *   * *   * * * *
PET Wrap *   * * * *   * * *
PET Wrap(FR)   *   * *   * * * *
Teflon®   *   *     *> * *  
Ryton®   *           * *  
Nylon® *       * * * * *  
Nylon Multifilament * *       * * * *  
Carbon Fiber                    
Fiberglass * * *     * * * *  
Reflex*                    
Mylar*                    
Kevlar * * *   *     *    
Dura-Flex Professional                    
Test Method
Standard
                   

* MIL-1-7444, MIL-STD 810 / #508, MIL-E-5272, MIL-1-631

 

Grades Outgassing Oxygen Index Specific Gravity g/cc Halogen Free
Insultherm low N/A 1.0 - 1.8 y
PET Standard med 21 1.38 y
Heavy Wall med 21 1.38 y
Flame Retardant med 31 1.38 y
Halar® low 64 1.68 y
Fray Resistant med 21 1.38 y
Fray Resistant (FR) med 31 1.38 y
PET Wrap med 23 1.38 y
PET Wrap (FR) med 31 1.38 y
Flexo Super Duty high 22 1.14 y
Teflon® v.low 95 2.10 y
Ryton® low 40 1.37 y
Nylon® high 22 1.14 y
Nylon Multifilament high 22 1.14 y
Carbon Fiber     1.75-1.85  
Fiberglass na     y
Reflex*        
Mylar*        
Kevlar   29 1.44 y
Dura-Flex Professional high 22   y
Insultherm Header Wrap n/a n/a 2.2 - 2.6 y
Test Method
Standard
  ASTM
D-2863
ASTM
D-792
 

 

The contents and illustrations contained herein are believed to be reliable. The manufacturer & distributor make no warranties as to their accuracy or completeness & disclaims any liability in connection with their use. The manufacturer & distributor’s only obligations are those in standard terms of sale for this product & they will not be liable for any consequential or other damages arising due to misuse of this product. Users should make their own evaluation to determine the suitability of the product for their unique & specific applications.

UL Recognized Component    flame test   csa logo