3M™ Fire Barrier CP 25WB+ Caulk

Intumescent Latex Caulk Seals Out Fire, Water, Smoke, and Noxious Gases


FP-3M-CP25WB-T
Qty:  

What's special about this fire barrier caulk?

  • Water Base: Easy clean up, no special handling, routine disposal
  • Intumescent: Expands when heated to seal around items consumed by fire
  • Endothermic: Absorbs heat energy, releases chemically bound water
  • Thixotropic: Will not sag or run in overhead or vertical applications
  • Click for More Features
  •  
  • UL ClassifiedFM Approved

3M Fire Caulk is a premium elastomeric latex caulk designed for use as a one-part fire, smoke, noxious gas and water sealant. In addition, the unique intumescent property of this material (expands when heated) means that as cable or pipe insulation is consumed by fire, 3M Fire Caulk expands to maintain the penetration seal.

Please Note: Pail orders ship in 5 Business days.

Part # Package Size Usage Price
FP-3M-CP25WB-T 10.1 oz. Tube Lightweight easy to handle. Perfect for smaller jobs.
Qty:  
Manufacturer Direct
FP-3M-CP25WB-P 5 gallon Pail Great for bulk loading on large jobs. The most cost-effective way to caulk large areas.
Qty:  
Manufacturer Direct
  • Halogen-free
  • Fast dry : Tack-free in approximately 10-15 minutes
  • Paintable (Best results obtained after 72 hour cure)
  • Minimal shrinkage
  • Brown color
  • Water seal: Seals against inadvertent water spills in the unexpanded state
  • High caulk rate: 1000 g/min. with in. nozzle
  • Point contact allowed
  • Continuous Operating Temperature not to exceed 120°F (48°C)
  • Proudly made in the USA US flag
  •  

    CP 25WB+ Caulk features superior adhesion strength, caulk rate and no sag application with expanded UL Classified fire protection systems plus a halogen-free formula.

    3M Fire Barrier CP 25WB+ Caulk can be installed with a standard caulking gun, pneumatic pumping equipment or it can be easily applied with a putty knife or trowel. CP 25WB+ Caulk will bond to concrete, metals, wood, plastic and cable jacketing. No mixing is required.

     

    Applications
    Use to seal construction openings, blank openings and penetrating items against the passage of flame, noxious gas, smoke and water. Restores fire rated construction to original integrity. Also for use with 3M Brand Fire Barrier FS195+ Wrap/Strip and CS-195+ Composite Sheet.

     

    UL Fire Protection logos

    FILL, VOID OR CAVITY MATERIALS FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS.
    SEE UL DIRECTORY OF PRODUCTS CERTIFIED FOR CANADA AND UL FIRE RESISTANCE DIRECTORY 50L6.

    Product
    The firestopping caulk shall be a one-part, intumescent, latex elastomer. The caulk shall be capable of expanding a minimum of 3 times at 1000°F. The material shall be thixotropic and be applicable to overhead, vertical and horizontal firestops. The caulk shall be listed by independent test agencies such as UL or FM and be tested to, and pass the criteria of, ASTM E 814 Fire Test, tested under positive pressure. It shall comply with the requirements of the NEC (NFPA-70), BOCA, ICBO, SBCCI and NFPA Code #101.

     

    Typically Specified Divisions
    Division 7
    07270
    Thermal and Moisture Protection Firestopping
    Division 13
    13900
    Special Construction Fire Suppression and Supervisory Systems
    Division 15
    15250
    15300
    Mechanical
    Mechanical Insulation Fire Protection
    Division 16 Electrical
    16050
    Electrical
    Basic Electrical Materials and Methods

     

    Performance
      Unit Value
    Tack Free Time
    (ASTM C679-87)
    Minutes at 72°F (22°C) 10-15
    Expansion at 662°F (350°C)
    X 2.0-3.0
    Color
    Reddish Brown
    Density
    Lb./gal. (Kg/l) 11.2 (1,35)
    Adhesion
    All construction substrates Very Good
    Application
    Method Caulk guns, trowel, spatula pressurized pumps
    Durometer (hardness)
    Shore A 70

    ASTM E 84
       Flame Spread
       Smoke Development




    5
    0
    Solids
    Percent (%) by weight 79
    VOC
    Percent (%) by weight 0
    Odor
    Pleasant, non-irritating
    Flow Rate
       1/4 in. (6,35 mm)
       nozzle at 50 psi
    Grams/min. 1000
    Boeing Flow
    (Sag Characteristics)
    Inches 0

     

    Firestopping Properties
    Meets the criteria of ASTM E 814 Fire Test, tested under positive pressure.
    Consult current UL Fire Resistance Directory for systems listed under 3M Product CP 25WB+ Caulk.

     

    Firestopping Code Requirements

    ICBO Uniform
    Building Code (1997 Edition)
    SBCCI Standard
    Building Code (1997 Edition)
    BOCA Basic/National Building Code(1996 Edition) NFPA Life Safety Code 101 (1997 Edition)

    702
    DEFINITIONS

    706
    CONSTRUCTION JOINTS

    708
    WOOD FRAME CONSTRUCTION
    FIREBLOCKING

    709
    WALL & PARTITION PENETRATION
    PROTECTION

    709.3.2.2
    CURTAIN WALL GAP

    710
    FLOOR/CEILING OR ROOF/CEILING
    PENETRATION PROTECTION

    711.3
    SHAFT ALTERNATIVE

    714
    THROUGH-PENETRATION
    FIRESTOPS F&T REQUIREMENTS

    UBC STANDARD 7-1
    EQUIVALENT TO ASTM E 119

    UBC STANDARD 7-5
    EQUIVALENT TO ASTM E 814

    104.2.4
    PLANS MUST SHOW HOW
    INTEGRITY IS MAINTAINED FOR ASSEMBLIES PENETRATED

    202
    DEFINITIONS

    705.3
    WOOD FRAME CONSTRUCTION
    FIREBLOCKING

    705.3.1.5
    CURTAIN WALL GAP

    705.4 (GENERAL)
    PENETRATIONS OF FIRE
    RATED ASSEMBLIES

    705.5 (WALLS)

    705.6 (FLOORS)

    705.7
    FIRE RESISTANT JOINT
    SYSTEMS
    702.0
    REVISED AND EXPANDED DEFINITIONS
    FOR PENETRATIONS AND JOINTS

    703.1
    CONSTRUCTION DOCUMENTS SHALL
    INDICATE DETAILS AND MATERIALS FOR PROVIDING RATINGS AT JOINTS AND PENETRATIONS

    703.1.1
    PENETRATIONS AND JOINTS SHALL NOT BE CONCEALED FROM VIEW BEFORE INSPECTION

    703.2
    BUILDINGS FOR MORE THAN TWO STORIES SHALL INDICATE ALL PENETRATIONS

    704.1.1
    SUFFICIENT DATA SHALL BE AVAILABLE TO JUSTIFY UNTESTED MATERIALS USED FOR RESTORATION OF FIRE RATINGS

    707.0
    FIRE WALLS AND PARTY WALLS

    707.10
    PENETRATIONS - REFERS TO 714

    707.8
    JOINTS - REFERS TO

    709.7

    709.0
    FIRE SEPARATION ASSEMBLIES
    709.6
    PENETRATIONS - REFER
    TO 714

    709.7
    JOINTS

    711.0
    FIRE PARTITIONS

    711.6
    PENETRATIONS - REFERS TO 714

    711.7
    JOINTS - REFER TO 709.7

    713.0
    FLOOR/CEILING AND ROOF/CEILING
    ASSEMBLIES

    713.2
    CURTAIN WALL GAP

    713.4
    PENETRATIONS - REFERS TO 714

    713.5
    JOINTS - REFERS TO 709.7

    714.0
    PENETRATIONS - ALL REQUIREMENTS
    (GENERAL)

    714.1 THROUGH 714.1.6.2 WALL ASSEMBLIES

    714.2 THROUGH 714.2.6.5 FLOOR/CEILING AND
    ROOF/CEILING ASSEMBLIES

    714.3 THROUGH 714.3.2
    NONRATED ASSEMBLIES

    721.0
    FIREBLOCKING AND
    DRAFTSTOPPING
    6-2.3.2.4
    PENETRATIONS AND
    MISC. OPENINGS&FIRE BARRIERS

    6.2.4.2, EXCEPTION
    5 OPENINGS (EXPANSION
    OR SEISMIC JOINTS) IN
    FLOORS

    APPENDIX
    A-6-2.4.2

    6-3.6.1
    PENETRATIONS AND
    MISC. OPENINGS
    IN FLOORS AND SMOKE
    BARRIERS

    NFPA #221

    FIRE WALLS AND

     

    NFPA
    Code 70 NEC
    National Electric Code


    300-21 FIRESTOPPING

     

    CABO
    One and Two Family Dwelling Code
    (1995 Edition)


    602.7
    FIRESTOPPING
    (FIREBLOCKING IN OTHER
    MODEL CODES)

     

    FM Approved; Omega Point Lab Listed; UL Classified

    FILL, VOID OR CAVITY MATERIALS FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS.
    SEE UL DIRECTORY OF PRODUCTS CERTIFIED FOR CANADA AND UL FIRE RESISTANCE DIRECTORY 50L6.

    >
    Related Articles



     

    How-To Corner



     

     

    Installation Techniques:

     

    cross section pipe through concrete floor
    cross section insulated cables through concrete wall
    cross section pipes through concrete

     


    Shown are examples of approved applications of CP 25WB+ Caulk. Additional drawings and details are available through your Authorized 3M Fire Protection Products Distributor.

    Installation Notes:
    1. Metal Pipe/Conduit applications through nominal 12 in. (304,8 mm) outside diameter
      • Installed depth of CP 25WB+ Caulk depends on annular space.
      • When the annular space is less than 1-1/4 in. (31,8 mm), a 1/2 in. (12,7 mm) minimum depth of CP 25WB+ Caulk is required.
      • When the annular space is greater than 1-1/4 in. (31,8 mm), a 1 in. (25,4 mm) minimum depth of CP 25WB+ Caulk is required.
      • Common building materials, such as backer rod may be used for metal pipe applications.
    2. Metal Pipe applications larger than nominal 12 in. (304,8 mm) outside diameter.
      • All cases require a 1 in. (25,4mm) minimum depth of CP 25WB+ Caulk.
    3. Insulated Cable Applications.
      • All cases require a 1 in. (25,4mm) minimum depth of CP 25WB+ Caulk.
      • All cases require mineral wool (safing) for packing.
    4. Fiberglass Insulated Pipe Applications.
      • 1 in. (25,4 mm) of fiberglass insulation on up to a nominal 12 in. (304,8 mm) of metal pipe may be firestopped with a 1 in. (25,4 mm) depth of CP 25WB+ Caulk.
      • 1 in. (25,4 mm) depth of mineral wool packing required
    Maintenance:

    The CP 25WB+ Caulk is stable under normal storage conditions and has a one year shelf life. Normal stock and stock rotation are recommended.
    Recommended:
    Store between 40°F (4°C)-90°F (32°C) for maximum shelf life. Keep from freezing.

     

    Warranty and Limited Remedy:

    This product will be free from defects in material and manufacture for a period of ninety (90) days from date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
    User is responsible for determining whether the 3M product is fit for a particular purpose and suitable for user’s method of application. If this 3M product is proved to be defective within the warranty period stated above, your exclusive remedy and 3M’s sole obligation shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product.

    Limitation of Liability:

    Except where prohibited by law, 3M will not be liable for any loss or damage arising from the use of this 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability.

    Request A Quote

    Did you know that we can give you a quote for most of our products, including shipping?

    You can also call us toll free 1-833-3CABLEORG (1-833-322-2536)

    Questions & Answers

    Question:

    tubing - Can this be used on pex tubing

    Asked by Anonymous user on 11.39 AM Tuesday, 15 July, 2014

    Answer:
    • - Thank you for your question. I believe this item is designed to work with rigid surfaces, flexible things like PEX tubing would not benefit from this product.

      Fernando M. on 11.49 AM Wednesday, 16 July, 2014
    Question:

    can it be used in a electrial box with no bare wires - Want to stop air leak in box no bare wires

    Asked by Anonymous user on 05.14 PM Monday, 02 February, 2015

    Answer:
    • - Thank you for your question. That seems like a reasonable application.

      Fernando M. on 04.09 PM Wednesday, 18 February, 2015
    Question:

    Our electrician used this product by spreading it at the back and sides of the electrical box instead of using a molded putty. With the way they applied this product, will it meet the 1 hour rated wall requirement

    Asked by Anonymous user on 08.57 PM Thursday, 19 October, 2017

    Answer:
    • - Yes, it will meet the 1 hour requirement.

      andrew b. on 04.00 PM Monday, 30 October, 2017

    Do you have any questions about this product?
    Let our experts and customers resolve all your doubts