Tripp Lite Omni VS Series UPS Systems
The Solution to Frequent Brownout Power Problems
What's special about this UPS?
- AVR technology ensures that your sensitive electronics run smoothly during power surges or drops.
- HID-compliance makes it possible for the system to shutdown without any loss of data during extended power outages, and enables direct integration with built-in power management and auto-shutdown features of Windows and MAC OS X.
- In addition to providing basic power protection, your telephone, DSL and Ethernet lines are protected from surge damage.
- Click for More Features
The Omni VS series UPS is perfect for entry-level PCs, networked workstations, point-of-sale equipment, small business phone systems, audio/video equipment and home theater systems.
Part # | Description | Volts | Full Load Runtime | Dimensions | Weight | Price |
---|---|---|---|---|---|---|
TL-OMNIVS800 | Omni VS UPS System | 800 | 3.5 min. | 14" H x 8.5" W x 10.5" D | 23.2 lbs. | Manufacturer Direct
|
TL-OMNIVS1000 | Omni VS UPS System | 1000 | 3.5 min. | 14" H x 8.5" W x 10.5" D | 23.2 lbs. | Manufacturer Direct
|
TL-OMNIVS1500 | Omni VS UPS System | 1500 | 4 min. | 15.5" H x 11" W x 11.25" D | 30 lbs. | Manufacturer Direct
|
TL-OMNIVS1500XL | Omni VS XL UPS System | 1500 | 4.5 min. | 15.5" H x 11" W x 11.25" D | 30 lbs. | Manufacturer Direct
|
If you find that your area is frequently plagued by brownouts, or a reduction in power, this series is optimal for preventing work interruptions due to power problems.
OMNIVS800 Omni VS UPS System
OMNIVS1000 Omni VS UPS System
OMNIVS1500 Omni VS UPS System
OMNIVS1500XL Omni VS UPS System
Estimated Runtime - Loads in Watts | |||||||||||||
UPS | 20W | 40W | 60W | 80W | 100W | 200W | 300W | 400W | 500W | 600W | 700W | 800W | 900W |
TL-OMNIVS800 | 194 | 94 | 59 | 42 | 32 | 13 | 7.1 | 4.5 | - | - | - | - | - |
TL-OMNIVS1000 | 270 | 133 | 84 | 60 | 46 | 19 | 11 | 6.8 | 3.5 | - | - | - | - |
TL-OMNIVS1500 | 294 | 177 | 124 | 93 | 74 | 34 | 20 | 14 | 8.3 | 7.3 | 6.4 | 5.2 | 4.3 |
TL-OMNIVS1500XL | 323 | 188 | 129 | 96 | 76 | 34 | 21 | 14 | 11 | 8.1 | 6.4 | 5.2 | 4.3 |
All runtime values are in minutes
TL-OMNIVS800 | TL-OMNIVS1000 | TL-OMNIVS1500 | TL-OMNIVS1500XL | |
SYSTEM OVERVIEW | ||||
Voltage compatibility: | 120VAC | 120VAC | 120VAC | 120VAC |
---|---|---|---|---|
Frequency compatibility: | 60 Hz | 60 Hz | 60 Hz | 60 Hz |
OUTPUT | ||||
Output VA: | 800 | 1000 | 1500 | 1500 |
Output watts: | 475 | 500 | 940 | 940 |
Output nominal voltage: | 120VAC | 120VAC | 120VAC | 120VAC |
Line Mode Output voltage regulation: | - | - | Sine wave line voltage 120V (-18%/8%) | Sine wave line voltage 120V (-18%/8%) |
Battery Mode Output voltage regulation: | PWM sine wave output 115V ±5% | PWM sine wave output 115V ±5% | PWM sine wave output 120V ±5% | PWM sine wave output 120V ±5% |
Line Mode Output frequency regulation: | Passes line frequency of 60Hz ±10% | Passes line frequency of 60Hz ±10% | Passes line frequency of 60Hz ±10% | Passes line frequency of 60Hz ±10% |
Battery Mode Output frequency regulation: | Inverter output regulated to 60Hz ±0.5Hz | Inverter output regulated to 60Hz ±0.5Hz | Inverter output regulated to 60Hz ±0.5Hz | Inverter output regulated to 60Hz ±0.5Hz |
Outlet quantity/type: | 7 NEMA 5-15R | 8 NEMA 5-15R | 8 NEMA 5-15R | 8 NEMA 5-15R |
INPUT | ||||
Maximum input amps: | 12A | 12A/1440W | 12A | 12A |
Input connection type: | NEMA 5-15P right-angle plug | NEMA 5-15P right-angle plug | NEMA 5-15P | NEMA 5-15P |
Input cord length: | 6' 14 gauge | 6' 14 gauge | 6' 14 gauge | 6' 14 gauge |
Recommended electrical service: | 15A 120V | 15A 120V | 15A 120V | 15A 120V |
BATTERY | ||||
Full load runtime: | 3.5 minutes (800VA) | 3.5 minutes (1000VA) | 4 minutes (1500VA) | 4.5 minutes (1500VA) |
Half load runtime: | 11.5 minutes (400VA) | 14 minutes (500VA) | 8.5 minutes (750VA) | 13 minutes (750VA) |
DC system voltage: | 12VDC | 12VDC | 24VDC | 24VDC |
Typical battery lifespan: | 3 to 6 years | 3 to 6 years | 3 to 6 years | 3 to 6 years |
Battery recharge rate: | 2 to 4 hours to 90% | 2 to 4 hours to 90% | 2 to 4 hours to 90% | 2 to 4 hours to 90% |
Replacement battery cartridge: | RBC51 | RBC52 (quantity 2) | RBC51 (quantity 2) | RBC51 (quantity 2) |
VOLTAGE REGULATION | ||||
Voltage regulation description: | Line interactive voltage regulation corrects brownouts as low as 83V back to usable values | Line interactive voltage regulation corrects brownouts as low as 83V back to usable values | AVR circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V | AVR circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V |
Over voltage correction: | - | - | Input voltages between 128 and 147VAC are reduced by 12% | Input voltages between 128 and 147VAC are reduced by 12% |
Direct pass through: | Voltages of 106V+ are passed through to connected equipment unchanged | Voltages of 106V+ are passed through to connected equipment unchanged | Input voltages between 108 and 127VAC are passed on to connected equipment unchanged | Input voltages between 108 and 127VAC are passed on to connected equipment unchanged |
Brownout correction: | Input voltages between 83 and 105 are boosted by 14% | Input voltages between 83 and 105 are boosted by 14% | Input voltages between 93 and 107VAC are boosted by 14% | Input voltages between 93 and 107VAC are boosted by 14% |
Severe brownout correction: | - | - | Input voltages between 75 and 92VAC are boosted by 30% | Input voltages between 75 and 92VAC are boosted by 30% |
LEDS ALARMS & SWITCHES | ||||
Front panel LEDs: | 4 status indicator LEDs: - Line power - Battery power - Battery low/replace - Voltage regulation operation |
4 status indicator LEDs: - Line power - Battery power - Battery low/replace - Overload |
5 status indicator LEDs: - Battery charge level - AC line voltage levels - Automatic voltage regulation status - UPS load level - Replace battery warning |
5 status indicator LEDs: - Battery charge level - AC line voltage levels - Automatic voltage regulation status - UPS load level - Replace battery warning |
Audible alarms - assuming full load: | Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains. | Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains. | Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains. | Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains. |
Front panel switches: | - (1) main on/off power - (1) dual function alarm cancel/self test button |
- (1) main on/off power - (1) dual function alarm cancel/self test button |
- (1) main on/off power - (1) dual function alarm cancel/self test button |
- (1) main on/off power - (1) dual function alarm cancel/self test button |
SURGE/NOISE SUPPRESSION | ||||
AC surge suppression: | 480 joules | 480 joules | 510 joules | 510 joules |
AC suppression response time: | Instantaneous | Instantaneous | Instantaneous | Instantaneous |
Dataline suppression: | Tel/DSL/Ethernet | Tel/DSL/Ethernet | Tel/DSL/Ethernet | Tel/DSL/Ethernet |
EMI/RFI AC noise suppression: | Yes | Yes | Yes | Yes |
PHYSICAL | ||||
Shipping weight: | 23.2 lbs. (10.5 kg) | 23.2 lbs. (10.5 kg) | 30 lbs. (13.5 kg) | 30 lbs. (13.5 kg) |
Shipping dimensions: | 14"H x 8.5"W x 10.5"D (35.6 x 21.6 x 26.7 cm) |
14"H x 8.5"W x 10.5"D (35.6 x 21.6 x 26.7 cm) |
15.5"H x 11"W x 11.25"D (39.4 x 28 x 28.6 cm) |
15.5"H x 11"W x 11.25"D (39.4 x 28 x 28.6 cm) |
Unit weight: | 21.2 lbs. (9.6 kg) | 21.2 lbs. (9.6 kg) | 28 lbs. (12.6 kg) | 28 lbs. (12.6 kg) |
Unit dimensions: | 10.75"H x 5.25"W x 7.25"D (27.3 x 13.4 x 18.4 cm) |
10.75"H x 5.25"W x 7.25"D (27.3 x 13.4 x 18.4 cm) |
11.75"H x 7.25"W x 7.5"D (29.8 x 18.4 x 19.1 cm) |
11.75"H x 7.25"W x 7.5"D (29.8 x 18.4 x 19.1 cm) |
Material of construction: | PVC | PVC | Polycarbonate | Polycarbonate |
Form factors supported: | Tower | Tower | Tower | Tower |
Cooling method: | Convection | Convection | Convection | Fan |
Battery Access: | Battery access door allows user replacement of UPS batteries. | Battery access door allows user replacement of UPS batteries. | Battery access door allows user replacement of UPS batteries, hot swappable battery replacement supported | Battery access door allows user replacement of UPS batteries, hot swappable battery replacement supported |
ENVIRONMENTAL | ||||
Operating Temperature: | 32°F to 104°F (0°C to 40°C) | 32°F to 104°F (0°C to 40°C) | 32°F to 104°F (0°C to 40°C) | 32°F to 104°F (0°C to 40°C) |
Storage Temperature: | 5°F to 122°F (-15°C to 50°C) | 5°F to 122°F (-15°C to 50°C) | 5°F to 122°F (-15°C to 50°C) | 5°F to 122°F (-15°C to 50°C) |
Relative Humidity: | 0 to 95%, non-condensing | 0 to 95%, non-condensing | 0 to 95%, non-condensing | 0 to 95%, non-condensing |
Line mode BTU/hr. max. | - | 43.6 | - | - |
Battery mode BTU/hr. max. | - | 147.8 | - | - |
COMMUNICATIONS | ||||
Network monitoring port: | USB | USB | USB | USB |
Cabling included: | USB and telephone | USB and telephone | USB and telephone | USB and telephone |
Software: | PowerAlert download | PowerAlert download | PowerAlert download | PowerAlert download |
WatchDog compatibilty: | Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications | Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications | Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications | Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications |
LINE/BATTERY TRANSFER | ||||
Transfer time from line power to battery mode: | 2 to 4 milliseconds | 2 to 4 milliseconds | 2 to 4 milliseconds | 2 to 4 milliseconds |
Low voltage transfer to battery power: | Switches to battery power as line voltage decreases to 83V or less. Resets to line power mode as line voltage increases to 87V or more | Switches to battery power as line voltage decreases to 83V or less. Resets to line power mode as line voltage increases to 87V or more | Switches to battery power as line voltage decreases to 75V or less. Resets back to line power mode as line voltage increases to 79V or more | Switches to battery power as line voltage decreases to 75V or less. Resets back to line power mode as line voltage increases to 79V or more |
High voltage transfer to battery power: | Switches to battery power as line voltage increases to 147V or higher. Resets to line power mode as line voltage decreases to 143V or less. | Switches to battery power as line voltage increases to 147V or higher. Resets to line power mode as line voltage decreases to 143V or less. | Switches to battery power as line voltage increases to 147Vs or higher. Resets back to line power mode as line voltage decreases to 143V or less. | Switches to battery power as line voltage increases to 147V or higher. Resets back to line power mode as line voltage decreases to 143V or less. |
SPECIAL FEATURES | ||||
Cold Start: | Yes | Yes | Yes | Yes |
Appearance: | Black | Black | Black | Black |
CERTIFICATIONS | ||||
Certifications: | Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), Class B (emissions), NOM (Mexico), FCC Part 68 Industry Canada (telecommunications), RoHS Compliant | Tested to UL1778 (USA), cUL (Canada), Class B (emissions), NOM (Mexico), FCC Part 68 Industry Canada (telecommunications) | Tested to UL1778 (USA), CSA (Canada), NOM (Mexico), FCC Class B (Emissions) | Tested to UL1778 (USA), CSA (Canada), NOM (Mexico), FCC Class B (Emissions) |
WARRANTY | ||||
Manufacturer's product warranty: | 2-year | 2-year | 2-year | 2-year |
Connected equipment insurance (USA and Canada Only): | $200,000 | $200,000 | $200,000 | $200,000 |
Optional manufacturer's coverage: | 3 to 5 year warranties, next day and on-site warranty coverage available | 3 to 5 year warranties, next day and on-site warranty coverage available | 3 to 5 year warranties, next day and on-site warranty coverage available | 3 to 5 year warranties, next day and on-site warranty coverage available |
Manuals
Related Articles
How-To Corner
Request A Quote
Did you know that we can give you a quote for most of our products, including shipping?
You can also call us toll free 1-833-3CABLEORG (1-833-322-2536)
Questions & Answers
Do you have any questions about this product?
Let our experts and customers resolve all your doubts