Tripp Lite Full Isolation Medical Grade Series UPS Systems

Reliable Power Source for Hospitals and Health Care Facilities


TL-OMNISMART350HG
Qty:  

What's special about these these uninterruptible power systems?

  • Equipped with a built-in faraday-shielded isolation transformer to reduce leaks and limit line noise.
  • UL 60601-1 listed for use in hospitals and healthcare facilities, giving you the peace of mind that critical equipment will maintain power during power outages and emergencies.
  • AVR keeps equipment operating smoothly during low voltage periods or brownouts without draining the battery.
  • Click for More Features
  •  
  • ULUL ClassifiedFCC

These medical grade UPS systems can eliminate disruptions and damage to sensitive equipment and make your power sources more reliable.

Please Note: They are NOT recommended for life support applications

Part # Description Volts Full Load Runtime Dimensions Weight Price
TL-OMNISMART350HG Omni Smart UPS System 330 18 min. 10.75" H x 5.25" W x 7.25" D 26.5 lbs
Qty:  
Manufacturer Direct
TL-SMART700HG SmartPro UPS System 700 18 min. 12.75" H x 7.5" W x 9" D 48 lbs
Qty:  
Manufacturer Direct
TL-SMART1200XLHG SmartPro XL Medical Grade UPS System 1000 10 min. 18.25" H x 11.75" W x 13.5" D 49.2 lbs
Qty:  
Manufacturer Direct

OmniSmart Full Isolation UPS Systems are ideal for medical applications, and allow you to install a single battery backup solution to provide all the benefits of a dedicated AC input line without the expense and inconvenience of running special circuits and upgrading site wiring.

  • Built in communication ports
  • Includes (4) high quality protected hospital-grade outlets and a 6' cord
  • Extended runtime capability on select models
  • Full-isolation UPS system is a key feature when dealing with sensitive equipment and operations.
  • Consistent battery power will keep systems up and running through short blackouts, and give you time to safely shut down during longer ones.
  • Each AC outlet prevents damage from lightning and surges
  • Low 100µA leakage of current from connected healthcare equipment.
  • Each of these models feature a hospital-grade plug and receptacles designed for use both inside and outside of patient-care areas.
  • Resistant to electrostatic discharge
  • Equipped with battery replacement door and back panel grounding lug
  • Provides surge protection, line isolation and EMI/RFI noise filtering
  • Complete remote monitoring cabling included
  • PowerAlert UPS management software available via free download
  • 2-year manufacturer's warranty


  • Applications:

  • Patient point-of-care solutions
  • Tele-medicine
  • Nurse's stations
  • Wireless communications systems
  • Electronic prescribing applications
  • Medical imaging
  • Mission critical equipment

  • *Not recommended for life support applications



    OMNISMART350HG Omni Smart UPS System

  • Supports loads up to 330VA/225W and maintains sine-wave 120V nominal output over an input range of 83 to 132V
  • Input: Hospital-grade NEMA 5-15P (120V 15A)
  • Output: 4 Hospital-grade NEMA 5-15R (120V)
  • 2-line phone suppression for TEL/DSL line protection
  • 46 minutes half load runtime (with 165VA load)
  • 18 minutes full load runtime (with 330VA load)
  • (1) DB9 serial port for network interface
  • (4) diagnostic LEDs
  • AC present
  • On battery
  • Voltage correction
  • Battery low/replace
  • Serial cable for remote monitoring, warranty information, and instruction manual included.


  • SMART700HG SmartPro UPS System

  • Supports loads up to 700VA/450 watts and maintains 120V nominal output over an input range of 82 to 142V
  • Input: NEMA 5-15P (120V 15A)
  • Output: 4 NEMA 5-15R (120V)
  • Line-interactive voltage regulation corrects brownouts and over voltages from 81 to 143 volts back to usable 120V output levels, without using battery power.
  • 42 minutes half load runtime (with 350VA load)
  • 18 minutes full load runtime (with 700VA load)
  • 5 diagnostic LEDs
  • AC present
  • On battery
  • Voltage correction
  • Overload
  • Battery low/replace
  • (1) USB and (1) DB9 monitoring cable, warranty information, and instruction manual included


  • SMART1200XLHG SmartPro XL Medical Grade UPS System

  • Supports loads up to 1000VA/750W and maintains 120V nominal output over an input range of 82 to 142V
  • Input: Hospital-grade NEMA 5-15P (120V 15A)
  • Output: 4 Hospital-grade NEMA 5-15R (120V)
  • Expandable runtime is available with the addition of one or more external battery packs (BP36V15-2U limit 1 or BP36V42-3U multi-pack compatible).
  • 28 min. half-load runtime (500VA/375W)
  • 10 min. full load runtime (1000VA/750W)
  • Equipped with USB and DB9 communication ports
  • 5 diagnostic LEDs
  • AC present
  • On battery
  • Voltage correction
  • Overload
  • Battery low/replace
  • PowerAlert Software and cabling, warranty information, and instruction manual included
  • Estimated Runtime - Loads in Watts
    UPS 20W 40W 60W 80W 100W 120W 140W 160W 180W 200W 260W 300W 340W 400W 500W 600W 700W
    TL-OMNISMART350HG 178 109 76 58 46 42 32 27 24 21 - - - - - - -
    TL-SMART700HG 347 218 155 119 95 - 66 - - 44 31 26 22 19 - - -
    TL-SMART1200XLHG 505 305 214 162 129 - - - - 60 - 37 - 25 19 15 12

    All runtime values are in minutes

     

      TL-OMNISMART350HG TL-SMART700HG TL-SMART1200XLHG
    SYSTEM OVERVIEW
    Voltage Compatibility: 120VAC 120VAC 120VAC
    Frequency Compatibility: 60 Hz 60 Hz 60 Hz
    OUTPUT
    Output VA: 330 700 1000
    Output Watts: 225 450 750
    Output Nominal Voltage: 120VAC 120VAC 120VAC
    Line Mode Output Voltage Regulation: Sine wave line voltage 120V (-18%/8%) Sine wave line voltage 120V (-18%/8%) Sine wave line voltage 120V (-18%/8%)
    Battery Mode Output Voltage Regulation: PWM sine wave output 120V ±5% - PWM sine wave output 115V ±5%
    Line Mode Output Frequency Regulation: Passes line frequency of 60Hz ±10% Passes line frequency of 60Hz ±10% Passes line frequency of 60Hz ±10%
    Battery Mode Output Frequency Regulation: Inverter output regulated to 60Hz ±0.5Hz - Inverter output regulated to 60Hz ±0.5Hz
    Outlet Quantity/Type: 4 NEMA 5-15R-HG Hospital-Grade 4 NEMA 5-15R-HG Hospital-Grade 4 NEMA 5-15R-HG Hospital-Grade
    INPUT
    Overload Protection: Resettable circuit breaker Resettable circuit breaker -
    Maximum Input Amps: 2.3A/250W 5.5A/550W 9.2A/860W
    Input Connection Type: NEMA 5-15P-HG Hospital-Grade NEMA 5-15P-HG Hospital-Grade NEMA 5-15P-HG Hospital-Grade
    Input Cord Length: 6' 14 gauge 6' 14 gauge 6' 14 gauge
    Recommended Electrical Service: 15A 120V 15A 120V 15A 120V
    BATTERY
    Full Load Runtime: 18 minutes (330VA) 18 minutes (700VA) 10 min. (1000VA)
    Half Load Runtime: 46 minutes (165VA) 42 minutes (350VA) 28 min. (500VA)
    DC System Voltage: 12VDC 36VDC 36VDC
    Typical Battery Lifespan: 3-6 years, depending on usage 3-6 years, depending on usage 3-6 years, depending on usage
    Battery Recharge Rate: 2-4 hours to 90% 2-4 hours to 90% 2-4 hours to 90%
    Replacement Battery Cartridge: RBC52 (quantity 2) - -
    VOLTAGE REGULATION
    Voltage Regulation Description: 1 boost level of brownout correction to maintain usable, computer grade output. 2 boost levels of brownout correction and a single level of over voltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 81 to 143VAC 2 boost levels of brownout correction and a single level of over voltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 81 to 143VAC
    Over Voltage Correction: Input voltages between 126 and 143VAC are reduced by 9% Input voltages between 126 and 143VAC are reduced by 9% -
    Direct Pass Through: Input voltages between 108 and 147VAC are passed through unchanged Input voltages between 105 and 125VAC are passed through unchanged Input voltages between 105 and 125VAC are passed through unchanged
    Brownout Correction: Input voltages between 83 and 107VAC are boosted by 14% Input voltages between 96 and 106VAC are boosted by 10% Input voltages between 96 and 106VAC are boosted by 10%
    Severe Brownout Correction: Input voltages between 81 and 95VAC are boosted by 21% Input voltages between 81 and 95VAC are boosted by 21% -
    LEDS ALARMS & SWITCHES
    Front Panel LEDs: 4 status indicator LEDs:
    - Line power
    - Battery power
    - Voltage regulation and
    -Battery low/replace status
    5 indicator LEDs:
    - Battery charge level
    - AC line voltage levels
    - Automatic voltage regulation status
    - UPS load level
    - Replace battery warning
    5 indicator LEDs:
    - Battery charge level
    - AC line voltage levels
    - Automatic voltage regulation status
    - UPS load level
    - Replace battery warning
    Alarms - Assuming Full Load: Indicates power failure, silenceable via alarm cancel switch. Once cancelled, alarm will resume when approximately 2 minutes of battery operation remain (assuming full load) 3 function audible alarm indicates:
    - Power failure conditions (4 beeps/10 sec)
    - Overload (continuous beeps)
    - Low battery (continuous tone)
    3 function audible alarm indicates:
    - Power failure conditions (4 beeps/10 sec)
    - Overload (continuous beeps)
    - Low battery (continuous tone)
    Front Panel Switches: - System enable
    - Self-test
    - Cancel Alarm
    - System enable
    - Self-test
    - Cancel Alarm
    - System enable
    - Self-test
    - Cancel Alarm
    SURGE/NOISE SUPPRESSION
    AC Surge Suppression: 480 joules 480 joules 480 joules
    AC Suppression Response Rime: Instantaneous Instantaneous Instantaneous
    Dataline Suppression: (2) Line Tel/DSL    
    EMI/RFI AC Noise Suppression: Yes Yes Yes
    PHYSICAL
    Shipping Weight: 26.5 lbs. (12 kg) 48 lbs. (21.8 kg) 49.2 lbs. (22.4 kg)
    Unit Weight: 25 lbs. (11.4 kg) 44.6 lbs. (20.2 kg) 45.2 lbs. (20.5 kg)
    Unit Dimensions: 10.75" H x 5.25" W x 7.25" D
    (27.3 x 13.3 x 18.4 cm)
    12.75" H x 7.5" W x 9" D
    (32.4 x 19.1 x 22.9 cm)
    18.25" H x 11.75" W x 13.5" D
    (46.4 x 29.8 x 34.3 cm)
    Material of Construction: PVC PVC PVC
    Form Factors Supported: Tower Tower Tower
    Cooling method: Convection Cooling via rear-exit cooling fan Cooling via rear-exit fan
    Battery Access: Battery access door allows hot swap battery replacement without powering connected equipment off Battery access door allows hot swap battery replacement without powering connected equipment off Battery access door allows hot swap battery replacement without powering connected equipment off
    ENVIRONMENTAL
    Operating Temperature: 32°F to 104°F (0° to 40°C) 32°F to 104°F (0° to 40°C) 32°F to 104°F (0° to 40°C)
    Storage Temperature: 5°F to 122°F (-15°C to 50°C) 5°F to 122°F (-15°C to 50°C) 5°F to 122°F (-15°C to 50°C)
    Relative Humidity: 0 to 95%, non-condensing 0 to 95%, non-condensing 0 to 95%, non-condensing
    COMMUNICATIONS
    Network Monitoring Port: DB9 (1) USB and (1) RS232 (1) USB and (1) DB9
    Cabling Included: (1) DB9 cable (1) USB to USB, (1) DB9 to DB9 (1) USB to USB, (1) DB9 to DB9
    Software: PowerAlert download PowerAlert download PowerAlert
    LINE/BATTERY TRANSFER
    Transfer Time From Line Power to Battery Mode: 2 to 4 milliseconds 2 to 4 milliseconds 2 to 4 milliseconds
    Low Voltage Transfer to Battery Power: 83V (resets to line power as voltage increases to 87V) 81V (resets to line power as voltage increases to 85V) 81V (resets to line power as voltage increases to 85V)
    High Voltage Transfer to Battery Power: 147V (resets to line power as voltage decreases to 143V) 143V (resets to line power as voltage decreases to 139V) 143V (resets to line power as voltage decreases to 139V)
    SPECIAL FEATURES
    Cold Start: Inverter can be cold started to enable temporary AC output during a power failure Inverter can be cold started to enable temporary AC output during a power failure Inverter can be cold started to enable temporary AC output during a power failure
    Appearance: Gray tower Gray tower Gray tower
    CERTIFICATIONS
    Certifications: Tested to UL1778 (USA, Series AGOM350KSR57HG), UL60601-1 (Medical), cUL (Canada), Class B (emissions), FCC Part 68 Industry of Canada (telecommunications) Tested to UL1778 (USA, Series AGSM700PSR3HG), UL60601-1 (Medical), cUL (Canada), FCC Class A (emissions) Tested to UL1778 (USA, Series AGSM1200PSR3HG), UL 60601-1 (Medical), cUL (Canada), FCC Class A (Emissions)
    WARRANTY
    Manufacturer's Product Warranty: 2-year 2-year 2-year
    Optional Coverage: 3-year, 5-year, next day and on-site warranty coverage available 3-year, 5-year, next day and on-site warranty coverage available in many areas; contact Tripp Lite 3-year, 5-year, next day and on-site warranty coverage available in many areas; contact Tripp Lite
    Manuals

     

    Related Articles



     

    How-To Corner



     

    Request A Quote

    Did you know that we can give you a quote for most of our products, including shipping?

    You can also call us toll free 1-833-3CABLEORG (1-833-322-2536)

    Questions & Answers

    Do you have any questions about this product?
    Let our experts and customers resolve all your doubts