Tripp Lite Full Isolation Medical Grade Series UPS Systems
Reliable Power Source for Hospitals and Health Care Facilities
What's special about these these uninterruptible power systems?
- Equipped with a built-in faraday-shielded isolation transformer to reduce leaks and limit line noise.
- UL 60601-1 listed for use in hospitals and healthcare facilities, giving you the peace of mind that critical equipment will maintain power during power outages and emergencies.
- AVR keeps equipment operating smoothly during low voltage periods or brownouts without draining the battery.
- Click for More Features
These medical grade UPS systems can eliminate disruptions and damage to sensitive equipment and make your power sources more reliable.
Please Note: They are NOT recommended for life support applications
Part # | Description | Volts | Full Load Runtime | Dimensions | Weight | Price |
---|---|---|---|---|---|---|
TL-OMNISMART350HG | Omni Smart UPS System | 330 | 18 min. | 10.75" H x 5.25" W x 7.25" D | 26.5 lbs | Manufacturer Direct
|
TL-SMART700HG | SmartPro UPS System | 700 | 18 min. | 12.75" H x 7.5" W x 9" D | 48 lbs | Manufacturer Direct
|
TL-SMART1200XLHG | SmartPro XL Medical Grade UPS System | 1000 | 10 min. | 18.25" H x 11.75" W x 13.5" D | 49.2 lbs | Manufacturer Direct
|
OmniSmart Full Isolation UPS Systems are ideal for medical applications, and allow you to install a single battery backup solution to provide all the benefits of a dedicated AC input line without the expense and inconvenience of running special circuits and upgrading site wiring.
Applications:
*Not recommended for life support applications
OMNISMART350HG Omni Smart UPS System
SMART700HG SmartPro UPS System
SMART1200XLHG SmartPro XL Medical Grade UPS System
Estimated Runtime - Loads in Watts | |||||||||||||||||
UPS | 20W | 40W | 60W | 80W | 100W | 120W | 140W | 160W | 180W | 200W | 260W | 300W | 340W | 400W | 500W | 600W | 700W |
TL-OMNISMART350HG | 178 | 109 | 76 | 58 | 46 | 42 | 32 | 27 | 24 | 21 | - | - | - | - | - | - | - |
TL-SMART700HG | 347 | 218 | 155 | 119 | 95 | - | 66 | - | - | 44 | 31 | 26 | 22 | 19 | - | - | - |
TL-SMART1200XLHG | 505 | 305 | 214 | 162 | 129 | - | - | - | - | 60 | - | 37 | - | 25 | 19 | 15 | 12 |
All runtime values are in minutes
TL-OMNISMART350HG | TL-SMART700HG | TL-SMART1200XLHG | |
SYSTEM OVERVIEW | |||
Voltage Compatibility: | 120VAC | 120VAC | 120VAC |
---|---|---|---|
Frequency Compatibility: | 60 Hz | 60 Hz | 60 Hz |
OUTPUT | |||
Output VA: | 330 | 700 | 1000 |
Output Watts: | 225 | 450 | 750 |
Output Nominal Voltage: | 120VAC | 120VAC | 120VAC |
Line Mode Output Voltage Regulation: | Sine wave line voltage 120V (-18%/8%) | Sine wave line voltage 120V (-18%/8%) | Sine wave line voltage 120V (-18%/8%) |
Battery Mode Output Voltage Regulation: | PWM sine wave output 120V ±5% | - | PWM sine wave output 115V ±5% |
Line Mode Output Frequency Regulation: | Passes line frequency of 60Hz ±10% | Passes line frequency of 60Hz ±10% | Passes line frequency of 60Hz ±10% |
Battery Mode Output Frequency Regulation: | Inverter output regulated to 60Hz ±0.5Hz | - | Inverter output regulated to 60Hz ±0.5Hz |
Outlet Quantity/Type: | 4 NEMA 5-15R-HG Hospital-Grade | 4 NEMA 5-15R-HG Hospital-Grade | 4 NEMA 5-15R-HG Hospital-Grade |
INPUT | |||
Overload Protection: | Resettable circuit breaker | Resettable circuit breaker | - |
Maximum Input Amps: | 2.3A/250W | 5.5A/550W | 9.2A/860W |
Input Connection Type: | NEMA 5-15P-HG Hospital-Grade | NEMA 5-15P-HG Hospital-Grade | NEMA 5-15P-HG Hospital-Grade |
Input Cord Length: | 6' 14 gauge | 6' 14 gauge | 6' 14 gauge |
Recommended Electrical Service: | 15A 120V | 15A 120V | 15A 120V |
BATTERY | |||
Full Load Runtime: | 18 minutes (330VA) | 18 minutes (700VA) | 10 min. (1000VA) |
Half Load Runtime: | 46 minutes (165VA) | 42 minutes (350VA) | 28 min. (500VA) |
DC System Voltage: | 12VDC | 36VDC | 36VDC |
Typical Battery Lifespan: | 3-6 years, depending on usage | 3-6 years, depending on usage | 3-6 years, depending on usage |
Battery Recharge Rate: | 2-4 hours to 90% | 2-4 hours to 90% | 2-4 hours to 90% |
Replacement Battery Cartridge: | RBC52 (quantity 2) | - | - |
VOLTAGE REGULATION | |||
Voltage Regulation Description: | 1 boost level of brownout correction to maintain usable, computer grade output. | 2 boost levels of brownout correction and a single level of over voltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 81 to 143VAC | 2 boost levels of brownout correction and a single level of over voltage adjustment to maintain usable, computer grade output without consuming battery power over an input voltage range of 81 to 143VAC |
Over Voltage Correction: | Input voltages between 126 and 143VAC are reduced by 9% | Input voltages between 126 and 143VAC are reduced by 9% | - |
Direct Pass Through: | Input voltages between 108 and 147VAC are passed through unchanged | Input voltages between 105 and 125VAC are passed through unchanged | Input voltages between 105 and 125VAC are passed through unchanged |
Brownout Correction: | Input voltages between 83 and 107VAC are boosted by 14% | Input voltages between 96 and 106VAC are boosted by 10% | Input voltages between 96 and 106VAC are boosted by 10% |
Severe Brownout Correction: | Input voltages between 81 and 95VAC are boosted by 21% | Input voltages between 81 and 95VAC are boosted by 21% | - |
LEDS ALARMS & SWITCHES | |||
Front Panel LEDs: | 4 status indicator LEDs: - Line power - Battery power - Voltage regulation and -Battery low/replace status |
5 indicator LEDs: - Battery charge level - AC line voltage levels - Automatic voltage regulation status - UPS load level - Replace battery warning |
5 indicator LEDs: - Battery charge level - AC line voltage levels - Automatic voltage regulation status - UPS load level - Replace battery warning |
Alarms - Assuming Full Load: | Indicates power failure, silenceable via alarm cancel switch. Once cancelled, alarm will resume when approximately 2 minutes of battery operation remain (assuming full load) | 3 function audible alarm indicates: - Power failure conditions (4 beeps/10 sec) - Overload (continuous beeps) - Low battery (continuous tone) |
3 function audible alarm indicates: - Power failure conditions (4 beeps/10 sec) - Overload (continuous beeps) - Low battery (continuous tone) |
Front Panel Switches: | - System enable - Self-test - Cancel Alarm |
- System enable - Self-test - Cancel Alarm |
- System enable - Self-test - Cancel Alarm |
SURGE/NOISE SUPPRESSION | |||
AC Surge Suppression: | 480 joules | 480 joules | 480 joules |
AC Suppression Response Rime: | Instantaneous | Instantaneous | Instantaneous |
Dataline Suppression: | (2) Line Tel/DSL | ||
EMI/RFI AC Noise Suppression: | Yes | Yes | Yes |
PHYSICAL | |||
Shipping Weight: | 26.5 lbs. (12 kg) | 48 lbs. (21.8 kg) | 49.2 lbs. (22.4 kg) |
Unit Weight: | 25 lbs. (11.4 kg) | 44.6 lbs. (20.2 kg) | 45.2 lbs. (20.5 kg) |
Unit Dimensions: | 10.75" H x 5.25" W x 7.25" D (27.3 x 13.3 x 18.4 cm) |
12.75" H x 7.5" W x 9" D (32.4 x 19.1 x 22.9 cm) |
18.25" H x 11.75" W x 13.5" D (46.4 x 29.8 x 34.3 cm) |
Material of Construction: | PVC | PVC | PVC |
Form Factors Supported: | Tower | Tower | Tower |
Cooling method: | Convection | Cooling via rear-exit cooling fan | Cooling via rear-exit fan |
Battery Access: | Battery access door allows hot swap battery replacement without powering connected equipment off | Battery access door allows hot swap battery replacement without powering connected equipment off | Battery access door allows hot swap battery replacement without powering connected equipment off |
ENVIRONMENTAL | |||
Operating Temperature: | 32°F to 104°F (0° to 40°C) | 32°F to 104°F (0° to 40°C) | 32°F to 104°F (0° to 40°C) |
Storage Temperature: | 5°F to 122°F (-15°C to 50°C) | 5°F to 122°F (-15°C to 50°C) | 5°F to 122°F (-15°C to 50°C) |
Relative Humidity: | 0 to 95%, non-condensing | 0 to 95%, non-condensing | 0 to 95%, non-condensing |
COMMUNICATIONS | |||
Network Monitoring Port: | DB9 | (1) USB and (1) RS232 | (1) USB and (1) DB9 |
Cabling Included: | (1) DB9 cable | (1) USB to USB, (1) DB9 to DB9 | (1) USB to USB, (1) DB9 to DB9 |
Software: | PowerAlert download | PowerAlert download | PowerAlert |
LINE/BATTERY TRANSFER | |||
Transfer Time From Line Power to Battery Mode: | 2 to 4 milliseconds | 2 to 4 milliseconds | 2 to 4 milliseconds |
Low Voltage Transfer to Battery Power: | 83V (resets to line power as voltage increases to 87V) | 81V (resets to line power as voltage increases to 85V) | 81V (resets to line power as voltage increases to 85V) |
High Voltage Transfer to Battery Power: | 147V (resets to line power as voltage decreases to 143V) | 143V (resets to line power as voltage decreases to 139V) | 143V (resets to line power as voltage decreases to 139V) |
SPECIAL FEATURES | |||
Cold Start: | Inverter can be cold started to enable temporary AC output during a power failure | Inverter can be cold started to enable temporary AC output during a power failure | Inverter can be cold started to enable temporary AC output during a power failure |
Appearance: | Gray tower | Gray tower | Gray tower |
CERTIFICATIONS | |||
Certifications: | Tested to UL1778 (USA, Series AGOM350KSR57HG), UL60601-1 (Medical), cUL (Canada), Class B (emissions), FCC Part 68 Industry of Canada (telecommunications) | Tested to UL1778 (USA, Series AGSM700PSR3HG), UL60601-1 (Medical), cUL (Canada), FCC Class A (emissions) | Tested to UL1778 (USA, Series AGSM1200PSR3HG), UL 60601-1 (Medical), cUL (Canada), FCC Class A (Emissions) |
WARRANTY | |||
Manufacturer's Product Warranty: | 2-year | 2-year | 2-year |
Optional Coverage: | 3-year, 5-year, next day and on-site warranty coverage available | 3-year, 5-year, next day and on-site warranty coverage available in many areas; contact Tripp Lite | 3-year, 5-year, next day and on-site warranty coverage available in many areas; contact Tripp Lite |
Manuals