Anamet Anaconda Sealtite® Type NMUA Liquid-Tight Non-Metallic Conduit

Liquid Tight Conduit for Applications Where UL and CSA approvals are required


Conduit
ANA-39702
Qty:  


Connectors
ANA-500003
Qty:  

What's special about this conduit?

  • One-piece construction of rigid, non-metallic reinforcement embedded in flexible PVC wall for exceptional crush and corrosion resistance.
  • Durable, sunlight resistant and flame retardant thermoplastic PVC that resists heat, oil and chemical breakdown.
  • Conduit used with standard fittings for non-metallic conduit Type B for easy installation. IP 66/67 Rated when installed with approved fittings.
  • Approved for both exposed and concealed locations. Rated for temperature ranges of -17°F to +176°F (-27°C to +80°C).
  • Complies with NEC Article 356 and UL Standard 1660 File No. E-211327; CSA C22.2 File No. 020817.
  • Easy to install and cuts easily
  • Approved for direct burial and in concrete trade sizes 3/8" through 2"
  • Click for More Features
  •  
  • ULCSA Approved

NMUA Sealtite® Non-Metallic Liquid-Tight Flexible Conduit is specifically for use in situations that call for a liquid-tight conduit that is able to withstand vibration, movement, oil and corrosives. This item is for use both indoors and out, and is perfect for outdoor lighting, water treatment systems and HVAC equipment.

Part # Description Length Color Weight Price
ANA-39702 3/8" Non-Metallic Flexible Conduit 100' Gray 13 lbs
Qty:  
Manufacturer Direct
ANA-39712 1/2"Non-Metallic Flexible Conduit 100' Gray 13 lbs
Qty:  
Manufacturer Direct
ANA-39722 3/4"Non-Metallic Flexible Conduit 100' Gray 17 lbs
Qty:  
Manufacturer Direct
ANA-39731 1"Non-Metallic Flexible Conduit 100' Gray 26.5 lbs
Qty:  
Manufacturer Direct
ANA-39741 1-1/4"Non-Metallic Flexible Conduit 50' Gray 16 lbs
Qty:  
Manufacturer Direct
ANA-39753 1-1/2"Non-Metallic Flexible Conduit 50' Gray 23 lbs
Qty:  
Quick Ship
ANA-39761 2"Non-Metallic Flexible Conduit 50' Gray 33 lbs
Qty:  
Manufacturer Direct
  • Resistance to oils, water and most chemicals makes this perfect for harsh conditions
  • Smooth interior finish and outer surface facilitates easy wire pulling
  • Remains flexible from -5° to +176°F (-20° to +80°C)
  • One piece construction means you do not have to worry your conduit will come apart
  • Extra strength built in with a rigid non metallic reinforcement embedded in the PVC wall
  • Installs and cuts quickly and easily, which saves on overall labor costs
  • For use with non metallic Type B connectors
  • ACI File Numbers for CSA 20817, UL approved for direct burial applications, UL Std #1660, File #E-75863 for Type B conduit, For use per Article 356 of the National Electric Code
  • Connector Dimensions
    1. Material Safety Data Sheet (PDF) PDF
    2. Chemical, Oils, Solvents (PDF) PDF

     

    Construction Non-metallic PVC material
    Usage Inside, outside, and in corrosive applications in accordance with Article 356 of the NEC
    Temperature Ranges
      Dry Locations
      Wet Locations
      Oil Locations
    -17° to +176° F (-27° to +80° C)
    +140° F (+60° C)
    +158° F (+70° C)
    UL/CSA UL Std #1660, File #E-75863 and CSA File # 20817 as Type B non-metallic conduit
    Comparable Conduits Carlon Carflex (3/8" to 2") : Not UL Listed
    Spiraduct Rhino (3/8" to 2") : UL Listed
    Resistance Chemical, Oils, Solvents PDF PDF

     

     

    Part # Trade Size & Catalog # Nominal Internal Diameter Outside Diameter Approx Inside Bend Diam. Approx
    Weight
    Per 100 Ft
    Carton
        min. max. min. max.     Length NAED
    ANA-39702 NMUA-3/8 0.484" 0.505" 0.690" 0.710" 4" 13 lb 100' 39702
    ANA-39712 NMUA-1/2 0.620" 0.640" 0.820" 0.840" 7" 14 lb 100' 39712
    ANA-39722 NMUA-3/4 0.820" 0.840" 1.030" 1.050" 9" 16 lb 100' 39722
    ANA-39731 NMUA-1 1.041" 1.066" 1.290" 1.315" 13" 26 lb 100' 39731
    ANA-39741 NMUA-1-1/4 1.380" 1.410" 1.635" 1.660" 16" 34 lb 50' 39741
    ANA-39753 NMUA-1-1/2 1.575" 1.600" 1.865" 1.900" 18" 45 lb 50' 39753
    ANA-39761 NMUA-2 2.020" 2.045" 2.340" 2.375" 22" 62 lb 50' 39761
    Part # Connector Type Electrical Trade Size Dimension A Dimension B Dimension C K.O. Size Thread Type
    ANA-500003 Straight 3/4 in (21 mm) 1.60" 0.550" 1.7" 3/4" NPT
    ANA-500005 Straight 1-1/4" (35 mm) 2.293" 0.645" 2.4" 1-1/4" NPT
    ANA-500006 Straight 1-1/2" (41 mm) 2.175" 0.66" 2.67" 1-1/2" NPT
    ANA-500007 Straight 2" (53 mm) 4.85" 0.67" 5.8" 2" NPT
    ANA-500007 Straight 2" (53 mm) 4.85" 0.67" 5.8" 2" NPT
    ANA-500009 90 Degree Angle 1/2" (16 mm) 2.242" 0.562" 3.12" 1/2" NPT
    ANA-500010 90 Degree Angle 3/4" (21 mm) 2.55" 0.545" 3.6" 3/4" NPT
    ANA-500011 90 Degree Angle 1" (27 mm) 3.15" 0.63" 4.125" 1" NPT
    ANA-500012 90 Degree Angle 1-1/4" (35 mm) 3.42" 0.645" 5.2" 1-1/4" NPT
    ANA-500013 90 Degree Angle 1-1/2" (41 mm) 4.51" 0.66" 5.2" 1-1/2" NPT
    ANA-500014 90 Degree Angle 2" (53 mm) 4.85" 0.67" 5.8" 2" NPT
    Manuals




     

    Related Articles




     

    How-To Corner



     

     

    How to Cut Sealtite® Flexible Conduit:

    It is important to ensure your cuts are clean and square so that there is an accurate and tight connection. The conduit is pre-marked at 2” intervals for easy use, cuts and measurements. You should not use a saw to cut this conduit as that may create jagged, uneven surfaces.

    It is recommended that a band saw be used for these precise cuts. The suggested blade specification for the band saw is: 1/2” wide x 0.25” thick and has 24 teeth per inch.  You should set the blade speed at 350’ per minute.

     

    ANAMET Warranty

    Seller warrants its products to be free from defects in workmanship of material, provided that Buyer notify Seller in writing, within 90 days after delivery of the orders to Buyer's location, or completion of the work at Buyer's location, whichever is applicable. Upon receipt of such notification, seller shall repair and/or replace, as its option, any of its products which its examination shall disclose as defective in workmanship or material. This warranty is exclusive and in lieu of all warranties, whether oral or written, expressed, or implied. The only exception is the warranty of title. NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY. Ordinary wear and tear shall not be considered a defect in workmanship or material. This warranty does not apply if the products have been damaged by accident, abuse, misuse, modification, misapplication, or improper service.
    Seller shallin no event be liable for any incidental or consequential damages, losses, or expense for breach of warranty or for negligence.

    Request A Quote

    Did you know that we can give you a quote for most of our products, including shipping?

    You can also call us toll free 1-833-3CABLEORG (1-833-322-2536)

    Questions & Answers

    Do you have any questions about this product?
    Let our experts and customers resolve all your doubts