Tripp Lite Omni Smart UPS Systems

Specifically Designed to Accommodate Your Work Station's Needs


TL-OMNISMART500
Qty:  

What's special about this UPS system?

  • Equipped with AVR/line-interactive to offer voltage regulation, surge suppression and long-lasting battery support.
  • Protects your computers and electronic equipment from downtime, damage and data loss that can occur from unexpected power problems such as brownouts, blackouts, surges and line noise.
  • In addition to standard surge suppression, provides telephone, DSL and ethernet line surge protection.
  • Click for More Features
  •  
  • ULCSA ApprovedFCC

Tripp Lite Omni Smart UPS Systems have workstation optimized features which include USB port and telephone and DSL line surge suppression, voltage regulation, and long-lasting battery support.

Part # Description Volts Full Load Runtime Dimensions Weight Price
TL-OMNISMART500 UPS System 500 4 min. 12" H x 8.25" W x 9.25" D 15.4 lbs.
Qty:  
Manufacturer Direct
  • Supports hot-swap battery replacement so you can keep working while you exchange the battery.
  • Works with 120V/60Hz applications for USA, Canada, Mexico and more.
  • HID-compliant so that your computer can communicate with your software and allow auto shutdown.
  • Free PowerAlert software available from Tripplite.com.
  • The unit's ability to work indefinitely through low voltage (brownout) conditions means that you can continue working without interruption.
  • 2-year manufacturer's warranty
  • $200,000 Ultimate Lifetime Insurance (USA, Puerto Rico and Canada only)


  • Applications:

  • Entry-level PCs
  • Networked workstations
  • Point-of-sale equipment
  • Small business phone systems
  • Audio/video equipment
  • Home theater systems
  • Sensitive electronics


  • OMNISMART300PNP

  • Maintains 120V nominal output over an input range of 75 to 147V
  • Supports entry-level PC systems for up to 30 min. during power failures to enable a safe system shutdown.
  • Input: NEMA 5-15P (120V 15A)
  • Output: 3 battery-supported NEMA 5-15R (120V) AC outlets.
  • Supports a full load of 300VA/180W for 10.5 min. and a half load of 150VA/90W for 27 min.
  • Attractive black tower configuration.
  • Built-in audible alarm and 4 front panel LEDs indicate UPS system and line power status
  • USB and telephone interconnection cables and instruction manual with warranty information included.


  • OMNISMART500

  • Maintains 120V nominal output over an input range of 75 to 147V
  • Supports entry level PC systems for up to 30 min. during power failures to enable a safe system shutdown.
  • Input: NEMA 5-15P (120V 15A)
  • Output: 6 NEMA 5-15R (120V)(Includes 3 battery supported outlets, plus 3 additional surge suppression-only).
  • Maximum load of 500VA/300 watts for 4 min. and a half load of 250VA/150 watts for 15 min.
  • Built-in audible alarm and 4 front panel LEDs indicate UPS system and line power status.
  • Short circuit protection during AC and battery modes.
  • PowerAlert software, cabling, and instruction manual with warranty information included.


  • OMNISMART700

  • Maintains 120V nominal output over an input range of 75 to 147V
  • Supports entry-level PC systems for up to 45 min. during power failures to enable safe system shutdown.
  • Supports a full load of 700VA/450W for 4 min. and a half load of 350VA/225W for 17 min.
  • Includes 6 NEMA 5-15R outlets: 3 battery-supported and 3 surge suppression-only outlets, and a 6' AC line cord with NEMA 5-15P plug.
  • DB9 port and HID-compliant USB port enable unattended shutdown without data loss during extended power failures.
  • Built-in dataline suppression jacks protect a single dialup tel/DSL line or network ethernet line connection.
  • Built-in audible alarm and 4 front panel LEDs indicate UPS system and line power status.
  • DB9, USB and telephone interconnection cables and instruction manual with warranty information included.


  • OMNISMART1050

  • Maintains 120V nominal output over an input range of 75 to 147V
  • Supports a single entry level PC system for up to 60 min. during power failures to enable a safe system shutdown.
  • Input: NEMA 5-15P (120V 15A)
  • Output: 6 battery supported NEMA 5-15R (120V) outlets, 6' AC line cord.
  • Maximum load of 1050VA for 7 min. and a half load of 525VA for 23 min.
  • Upright tower configuration uses only 51 square inches of floor or desktop space.
  • Built-in audible alarm and 5 front panel LEDs indicate status of line power, battery power, battery low/replace, voltage regulation and overload status.
  • USB and telephone interconnection cables and instruction manual with warranty information included.


  • OMNISMART1400

  • Maintains 120V nominal output over an input range of 75 to 147V
  • Supports a single entry level PC system for up to 75 min. during power failures to enable a safe system shutdown.
  • Input: NEMA 5-15P (120V 15A)
  • Output: 6 battery supported NEMA 5-15R (120V) outlets
  • Supports a maximum load of 1400VA for 8 min. and half load of 700VA for 24 min.
  • Upright tower configuration uses only 66 square inches of floor or desktop space
  • USB interface supports timed inverter shutoff after unattended shutdown, activate self-test and 10 second reboot of connected equipment.
  • Built-in audible alarm and 5 front panel LEDs indicate status of line power, battery power, battery low/replace, voltage regulation and overload status.
  • USB and telephone interconnection cables and instruction manual with warranty information included.
  • Estimated Runtime - Loads in Watts
    UPS 20W 40W 60W 80W 100W 140W 200W 300W 400W 700W 900W
    TL-OMNISMART500 140 68 43 30 23 16 8.3 4 - - -

    All runtime values are in minutes

     

      TL-OMNISMART300PNP TL-OMNISMART500 TL-OMNISMART700 TL-OMNISMART1050 TL-OMNISMART1400
    SYSTEM OVERVIEW
    Voltage compatibility: 120VAC 120VAC 120VAC 120VAC 120VAC
    Frequency compatibility: 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz
    OUTPUT
    Output VA: 300 500 700 1050 1400
    Output watts: 180 300 450 705 940
    Output nominal voltage: 120VAC 120VAC 120VAC 120VAC 120VAC
    Line Mode Output voltage regulation: Sine wave line voltage 120V (-18%/8%) Sine wave line voltage 120V (-18%/8%) Sine wave line voltage 120V (-18%/8%) Sine wave line voltage 120V (-18%/8%) Sine wave line voltage 120V (-18%/8%)
    Battery Mode Output voltage regulation: PWM sine wave output 115V ±5% PWM sine wave output 120V ±5% PWM sine wave output 115V ±5% PWM sine wave output 115V ±5% PWM sine wave output 115V ±5%
    Line Mode Output frequency regulation: Passes line frequency of 60Hz ±10% Passes line frequency of 60Hz ±10% Passes line frequency of 60Hz ±10% Passes line frequency of 60Hz ±10% Passes line frequency of 60Hz ±10%
    Battery Mode Output frequency regulation: Inverter output regulated to 60Hz ±0.5Hz Inverter output regulated to 60Hz ±0.5Hz Inverter output regulated to 60Hz ±0.5Hz Inverter output regulated to 60Hz ±0.5Hz Inverter output regulated to 60Hz ±0.5Hz
    Outlet quantity/type: 3 NEMA 5-15R 6 NEMA 5-15R 6 NEMA 5-15R 6 NEMA 5-15R 6 NEMA 5-15R
    INPUT
    Maximum input amps: 2.1A 12A 12A 6.7A 9.2A
    Input connection type: NEMA 5-15P right-angle plug NEMA 5-15P right-angle plug NEMA 5-15P NEMA 5-15P right-angle plug NEMA 5-15P
    Input cord length: 6' 16 gauge 6' 16 gauge 6' 16 gauge 6' 16 gauge 6' 16 gauge
    Recommended electrical service: 15A 120V 15A 120V 15A 120V 15A 120V 15A 120V
    BATTERY
    Full load runtime: 10.5 minutes (300VA) 4 minutes (500VA) 4 minutes (700VA) 7 minutes (1050VA) 8 minutes (1400VA)
    Half load runtime: 27 minutes (150VA) 15 minutes (250VA) 17 minutes (350VA) 23 minutes (525VA) 24 minutes (700VA)
    DC system voltage: 12VDC 12VDC 12VDC 18VDC 36VDC
    Typical battery lifespan: 3 to 6 years 3 to 6 years 3 to 6 years 3 to 6 years 3 to 6 years
    Battery recharge rate: 2 to 4 hours to 90% 2 to 4 hours to 90% 2 to 4 hours to 90% 2 to 4 hours to 90% 2 to 4 hours to 90%
    Replacement battery cartridge: RBC51 RBC51 RBC52 (quantity 2) RBC52 (quantity 3) RBC53
    VOLTAGE REGULATION
    Voltage regulation description: AVR circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V AVR circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V AVR circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V AVR circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V AVR circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V
    Over voltage correction: Input voltages between 128 and 147VAC are reduced by 12% Input voltages between 128 and 147VAC are reduced by 12% Input voltages between 128 and 147VAC are reduced by 12% Input voltages between 128 and 147VAC are reduced by 12% Input voltages between 128 and 147VAC are reduced by 12%
    Direct pass through: Input voltages between 108 and 127VAC are passed on to connected equipment unchanged Input voltages between 108 and 127VAC are passed on to connected equipment unchanged Input voltages between 108 and 127VAC are passed on to connected equipment unchanged Input voltages between 108 and 127VAC are passed on to connected equipment unchanged Input voltages between 108 and 127VAC are passed on to connected equipment unchanged
    Brownout correction: Input voltages between 93 and 107VAC are boosted by 14% Input voltages between 93 and 107V AC are boosted by 14% Input voltages between 93 and 107V AC are boosted by 14% Input voltages between 93 and 107V AC are boosted by 14% Input voltages between 93 and 107V AC are boosted by 14%
    Severe brownout correction: Input voltages between 75 and 92VAC are boosted by 30% Input voltages between 75 and 92VAC are boosted by 30% Input voltages between 75 and 92VAC are boosted by 30% Input voltages between 75 and 92VAC are boosted by 30% Input voltages between 75 and 92VAC are boosted by 30%
    LEDS ALARMS & SWITCHES
    Front panel LEDs: 4 status indicator LEDs:
    - Line power
    - Battery power
    - Battery low/replace
    - Voltage regulation operation
    4 status indicator LEDs:
    - Line power
    - Battery power
    - Battery low/replace
    - Overload
    4 status indicator LEDs:
    - Line power
    - Battery power
    - Battery low/replace
    - Overload
    5 status indicator LEDs:
    - Line power
    - Battery power
    - Battery low/replace
    - Voltage regulation operation
    - Overload
    5 status indicator LEDs:
    - Line power
    - Battery power
    - Battery low/replace
    - Voltage regulation operation
    - Overload
    Audible alarms - assuming full load: Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains. Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains. Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains. Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains. Indicates loss of utility power. Silence by pressing front panel alarm cancel button, alarm will re-sound when 2 minutes runtime remains.
    Front panel switches: - (1) main on/off power
    - (1) dual function alarm cancel/self test button
    - (1) main on/off power
    - (1) dual function alarm cancel/self test button
    - (1) main on/off power
    - (1) dual function alarm cancel/self test button
    - (1) main on/off power
    - (1) dual function alarm cancel/self test button
    - (1) main on/off power
    - (1) dual function alarm cancel/self test button
    SURGE/NOISE SUPPRESSION
    AC surge suppression: 480 joules 480 joules 510 joules 480 joules 480 joules
    AC suppression response time: Instantaneous Instantaneous Instantaneous Instantaneous Instantaneous
    Dataline suppression: Tel/DSL Tel/DSL Tel/DSL/Ethernet    
    EMI/RFI AC noise suppression: Yes Yes Yes Yes Yes
    PHYSICAL
    Shipping weight: 15 lbs. (6.8 kg) 15.4 lbs. (7 kg) 22 lbs. (10 kg) 30.5 lbs. (13.8 kg) 40lbs. (18.2 kg)
    Shipping dimensions: 12.25"H x 10"W x 8.5"D (31.1 x 25.4 x 21.6 cm) 12"H x 8.25 "W x 9.25"D (30.5 x 21 x 23.5 cm) 14"H x 8.25"W x 10.4"D (35.6 x 21 x 26.4 cm) 11.75"H x 7.25"W x 7.25"D (29.8 x 18.4 x 18.4 cm) 12.75"H x 7.5 "W x 9"D (32.4 x 19.1 x 22.9 cm)
    Unit weight: 13.5 lbs. (6.1 kg) 14 lbs. (6.4 kg) 20 lbs. (9.1 kg) 28 lbs. (13 kg) 36.4 lbs. (16.5 kg)
    Unit dimensions: 8.5"H x 5"W x 6.5"D (21.6 x 12.7 x 16.5 cm) 8.5"H x 5"W x 6.5"D (21.6 x 12.7 x 16.5 cm) 10.75"H x 5.25"W x 7.5"D (27.3 x 13.3 x 19.1 cm)
    Material of construction: PVC PVC PVC PVC PVC
    Form factors supported: Tower Tower Tower Tower Tower
    Cooling method: Convection Convection Convection Convection Convection
    Battery Access: Battery access door allows user replacement of UPS batteries. Battery access door allows user replacement of UPS batteries. Battery access door allows user replacement of UPS batteries. Battery access door allows user replacement of UPS batteries. Battery access door allows user replacement of UPS batteries.
    ENVIRONMENTAL
    Operating Temperature: 32°F to 104°F (0°C to 40°C) 32°F to 104°F (0°C to 40°C) 32°F to 104°F (0°C to 40°C) 32°F to 104°F (0°C to 40°C) 32°F to 104°F (0°C to 40°C)
    Storage Temperature: 5°F to 122°F (-15°C to 50°C) 5°F to 122°F (-15°C to 50°C) 5°F to 122°F (-15°C to 50°C) 5°F to 122°F (-15°C to 50°C) 5°F to 122°F (-15°C to 50°C)
    Relative Humidity: 0 to 95%, non-condensing 0 to 95%, non-condensing 0 to 95%, non-condensing 0 to 95%, non-condensing 0 to 95%, non-condensing
    COMMUNICATIONS
    Network monitoring port: USB (HID) USB USB (HID) and DB9 USB USB
    Cabling included: USB USB Complete cabling USB USB
    Software: PowerAlert download PowerAlert download PowerAlert download PowerAlert download PowerAlert download
    WatchDog compatibilty: Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications Yes, restore operation to locked equipment through soft reboot of application/OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications
    LINE/BATTERY TRANSFER
    Transfer time from line power to battery mode: 2 to 4 milliseconds 2 to 4 milliseconds 2 to 4 milliseconds 2 to 4 milliseconds 2 to 4 milliseconds
    Low voltage transfer to battery power: Switches to battery power as line voltage decreases to 75V or less. Resets back to line power mode as line voltage increases to 79V or higher. Switches to battery power as line voltage decreases to 75V or less. Resets back to line power mode as line voltage increases to 79V or higher. Switches to battery power as line voltage decreases to 75V or less. Resets back to line power mode as line voltage increases to 79V or higher. Switches to battery power as line voltage decreases to 75V or less. Resets back to line power mode as line voltage increases to 79V or higher. Switches to battery power as line voltage decreases to 75V or less. Resets back to line power mode as line voltage increases to 79V or higher.
    High voltage transfer to battery power: Switches to battery power as line voltage increases to 147V or higher. Resets back to line power mode as line voltage decreases to 143V or less. Switches to battery power as line voltage increases to 147V or higher. Resets back to line power mode as line voltage decreases to 143V or less. Switches to battery power as line voltage increases to 147V or higher. Resets back to line power mode as line voltage decreases to 143V or less. Switches to battery power as line voltage increases to 147V or higher. Resets back to line power mode as line voltage decreases to 143V or less. Switches to battery power as line voltage increases to 147V or higher. Resets back to line power mode as line voltage decreases to 143V or less.
    SPECIAL FEATURES
    Cold Start: Yes Yes Yes Yes Yes
    Appearance: Black Black Black Gray Gray
    CERTIFICATIONS
    Certifications: Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), Class B (emissions), NOM (Mexico), FCC Part 68 Industry Canada (telecommunications), RoHS Compliant Tested to UL1778 (USA), cUL (Canada), Class B (emissions), NOM (Mexico), FCC Part 68 Industry Canada (telecommunications) Tested to UL1778 (USA), cUL (Canada), Class B (emissions), NOM (Mexico), FCC Part 68 Industry Canada (telecommunications) Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), Class B (emissions), NOM (Mexico) Tested to UL1778 (USA), cUL (Canada), Class B (emissions), NOM (Mexico)
    WARRANTY
    Manufacturer's product warranty: 2-year 2-year 2-year 2-year 2-year
    Connected equipment insurance (USA and Canada Only): $200,000 $200,000 $200,000 $200,000 $200,000
    Optional manufacturer's coverage: 3 to 5 year warranties, next day and on-site warranty coverage available 3 to 5 year warranties, next day and on-site warranty coverage available 3 to 5 year warranties, next day and on-site warranty coverage available 3 to 5 year warranties, next day and on-site warranty coverage available 3 to 5 year warranties, next day and on-site warranty coverage available
    Manuals




     

    Related Articles



     

    How-To Corner



     

    Request A Quote

    Did you know that we can give you a quote for most of our products, including shipping?

    You can also call us toll free 1-833-3CABLEORG (1-833-322-2536)

    Questions & Answers

    Do you have any questions about this product?
    Let our experts and customers resolve all your doubts