Tripp Lite Digital UPS Systems
Higher Performance at Lower Cost
What's special about these UPS?
- Provides voltage regulation, surge suppression and long-life battery support for personal computers, home entertainment systems and media center.
- Large easy to read backlit LCD input voltage display rotates so it can be read in the horizontal or vertical position.
- Click for More Features
A UPS is an uninterruptable power supply system that provides backup power for your components in the event that you experience a blackout, brownout, surge or other unexpected electrical event. With the combination of a microcontroller unit (MCU) and digital signal processor (DSP) in a single chip, these digital UPS’s from Tripp-Lite allow higher performing power protection at a much lower cost.
Part # | Output Capacity | Network Monitoring Port | Dataline Suppression | Dimensions | Weight | Price |
---|---|---|---|---|---|---|
TL-OMNI650LCD | 650 VA / 350 W | 1 USB | — | 6.5" H x 15.5" W x 11" D | 14.6 lbs | Manufacturer Direct
|
TL-OMNI900LCD | 900 VA / 475 W | 1 USB | — | 6.5" H x 15.5" W x 11" D | 14.6 lbs | Manufacturer Direct
|
TL-SMART1000LCD | 1000 VA / 500 W | 1 USB | Tel/DSL & Coaxial | 6.5" H x 15.5" W x 11" D | 14.6 lbs | Manufacturer Direct
|
TL-SMART1200LCD | 1200 VA / 700 W | 1 DB9 & 1 USB | Tel/DSL & Ethernet | 7" H x 21" W x 14.5" D | 25 lbs | Manufacturer Direct
|
TL-SMART1500LCD | 1500 VA / 900 W | 1 DB9 & 1 USB | Tel/DSL & Ethernet | 7" H x 21" W x 14.5" D | 29 lbs | Manufacturer Direct
|
Traditionally, UPS systems have been designed as analog circuitry, however with the growing technology, digital UPS's are becoming more of a preference.
Model OMNI650LCD OmniSmart Digital UPS
Model OMNI900LCD OmniSmart Digital UPS
Model SMART1000LCD SmartPro Digital UPS
Model SMART1200LCD SmartPro Digital UPS
Model SMART1500LCD SmartPro Digital UPS
Estimated Runtime - Loads in Watts | |||||||||||||||||
UPS | 20W | 40W | 60W | 80W | 100W | 140W | 200W | 260W | 300W | 340W | 400W | 460W | 500W | 600W | 700W | 800W | 900W |
TL-OMNI650LCD | 155 | 73 | 45 | 32 | 24 | 16 | 9.2 | 5.7 | 4.5 | 3.5 | — | — | — | — | — | — | — |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TL-OMNI900LCD | 198 | 96 | 60 | 43 | 33 | — | 13 | — | 7.2 | — | 4.4 | 3.2 | — | — | — | — | — |
TL-SMART1000LCD | 198 | 96 | 60 | 43 | 33 | — | 13 | — | 7.1 | — | 4.3 | — | 3.0 | — | — | — | — |
TL-SMART1200LCD | 340 | 173 | 111 | 80 | 62 | — | 26 | — | 15 | — | 10 | — | 7.2 | 5.4 | 4.0 | — | — |
TL-SMART1500LCD | 294 | 177 | 123 | 93 | 73 | — | 33 | — | 20 | — | 14 | — | 10 | 7.7 | 6.0 | 4.9 | 3.5 |
All runtime values are in minutes
TL-OMNI650LCD | TL-OMNI900LCD | TL-SMART1000LCD | TL-SMART1200LCD | TL-SMART1500LCD | |
SYSTEM OVERVIEW | |||||
---|---|---|---|---|---|
Voltage Compatibility | 120VAC | 120VAC | 120VAC | 120VAC | 120VAC |
Frequency Compatibility | 60Hz | 60Hz | 60Hz | 60Hz | 60Hz |
OUTPUT | |||||
Output VA | 650 | 900 | 1000 | 1200 | 1500 |
Output Watts | 350 | 475 | 500 | 700 | 900 |
Output Nominal Voltage | 120VAC | 120VAC | 120VAC | 120VAC | 120VAC |
Output Voltage Regulation | PWM sine wave 115V +/-5% (battery mode) | ||||
Output Frequency Regulation | LINE MODE: Passes line frequency of 60Hz +/-10% BATTERY MODE: Inverter output regulated to 60Hz +/-0.5Hz |
||||
Outlet Quantity / Type | 8 NEMA 5-15R | 8 NEMA 5-15R | 8 NEMA 5-15R | 8 NEMA 5-15R | 8 NEMA 5-15R |
INPUT | |||||
Maximum Input Amps | 12A | 12A | 12A | 10A input circuit breaker | 8.5A |
Input Connection Type | NEMA 5-15P, right-angle plug | NEMA 5-15P, right-angle plug | NEMA 5-15P, right-angle plug | NEMA 5-15P | NEMA 5-15P |
Input Cord Length | 6ft (1.8m) | 6ft (1.8m) | 6ft (1.8m) | 6ft (1.8m) | 6ft (1.8m) |
Recommended Electrical Service | 120V 15A | 120V 15A | 120V 15A | 120V 15A | 120V 15A |
BATTERY | |||||
Full Load Runtime | 3.5 min. (650VA/350W) | 3 min. (900VA /475W) | 3 min. (1000VA /500w) | 4 min. (700W) | 3.5 min. (900W) |
Half Load Runtime | 12 min. (325VA /175W) | 10 min. (450VA /237W) | 9 min. (500VA /250w) | 12 min. (350W) | 13 min. (450W) |
DC System Voltage | 12 VDC | 12 VDC | 12 VDC | N/A | N/A |
Typical Battery Lifespan | 4-6 years, depending on usage | ||||
Battery Recharge Rate | 2-8 hours to reach 90% charge | — | — | 2-8 hours to reach 90% charge | 2-8 hours to reach 90% charge |
VOLTAGE REGULATION | |||||
Voltage Regulation Description | Line-interactive voltage regulation corrects brownouts as low as 89V back to usable values | Line-interactive voltage regulation corrects brownouts as low as 89V back to usable values | Line-interactive voltage regulation corrects brownouts as low as 89V back to usable values | Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V | Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120V nominal output, without using battery power, during brownouts to 75V and overvoltages to 147V |
Direct Pass Trough | N/A | Voltages of 105V and greater are passed through to connected equipment unchanged | Voltages of 105V and greater are passed through to connected equipment unchanged | Input voltages between 128VAC and 147VAC are reduced by 12% | Input voltages between 128VAC and 147VAC are reduced by 12% |
Brownout Correction | Input voltages between 89V and 104V are boosted by 14% | ||||
LEDS ALARMS & SWITCHES | |||||
Front panel LEDs | Front panel LCD screen with blue backlight offers continuous input line voltage data, plus UPS status information on line power status, battery power status, battery charge level and voltage regulation operation | ||||
Alarms | Audible alarm with 15-second delay sounds to indicate loss of utility power. Alarm can be silenced by pressing front panel alarm cancel button. Once silenced, alarm will re-sound when approximately 2 minutes runtime remain. | ||||
Switches | Includes 2 front panel switches, one main on/off power switch and one dual-function alarm cancel/self test button | ||||
SURGE / NOISE SUPPRESSION | |||||
AC Surge Suppression | 480 joules | 870 joules | 480 Joules | 480 Joules | 480 Joules |
AC Suppression Response Time | Instantaneous | Instantaneous | Instantaneous | Instantaneous | Instantaneous |
Dataline Suppression | N/A | N/A | Tel/DSL or Coaxial | Tel/DSL or Ethernet | Tel/DSL or Ethernet |
EMI / RFI AC Noise Suppression | Yes | Yes | Yes | Yes | Yes |
PHYSICAL | |||||
Unit Weight | 14.6 lbs (6.6 kg) | 14.6 lbs (6.6 kg) | 14.6 lbs (6.6 kg) | 25 lbs (11.4 kg) | 29 lbs (13.2 kg) |
Unit Dimensions | 6.5" H x 15.5" W x 11" D (16.5cm x 39.4cm x 27.9cm) | 6.5" H x 15.5" W x 11" D (16.5cm x 39.4cm x 27.9cm) | 6.5" H x 15.5" W x 11" D (16.5cm x 39.4cm x 27.9cm) | 7" H x 21" W x 14.5" D (17.8cm x 53.3cm x 36.8cm) | 7" H x 21" W x 14.5" D (17.8cm x 53.3cm x 36.8cm) |
Material of Construction | ABS | ABS | ABS | ABS | ABS |
Form Factors Supported | Rack/Tower | Rack/Tower | Rack/Tower | Rack/Tower | Rack/Tower |
Cooling Method | Convection | Convection | Convection | Convection | Convection |
Battery Access | n/a | Battery access door allows user replacement of UPS batteries | n/a | n/a | n/a |
Receptacle Color | Black | Black | Black | Black | Black |
ENVIRONMENTAL | |||||
Operating Temperature | 32° to 104° F (0° to 40° C) | 32° to 104° F (0° to 40° C) | 32° to 104° F (0° to 40° C) | 32° to 104° F (0° to 40° C) | 32° to 104° F (0° to 40° C) |
Storage Temperature | 5° to 122° F (-15° to 50° C) | 5° to 122° F (-15° to 50° C) | 5° to 122° F (-15° to 50° C) | 5° to 122° F (-15° to 50° C) | 5° to 122° F (-15° to 50° C) |
Relative Humidity | 0 to 95%, non-condensing | 0 to 95%, non-condensing | 0 to 95%, non-condensing | 0 to 95%, non-condensing | 0 to 95%, non-condensing |
Line Mode BTU/hr. (Max.) | n/a | n/a | n/a | 243.7 BTU/hr. | n/a |
COMMUNICATIONS | |||||
Network Monitoring Port | USB (HID) | USB (HID) | USB (HID) | DB9 and USB (HID) | DB9 and USB (HID) |
Software & Cabling Included | PowerAlert Software available for free download at www.tripplite.com. (User supplies USB cable.) | PowerAlert Software available for free download at www.tripplite.com. (User supplies USB cable.) | USB cabling included, PowerAlert software available for free download at www.tripplite.com | USB, DB9 and phone cables included; PowerAlert software available for free download at www.tripplite.com | USB cabling included, PowerAlert software available for free download at www.tripplite.com |
WatchDog Compatibility | Yes, compatible with Tripp Lite's Watchdog system service to restore operation to locked equipment through soft reboot of application / OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications | ||||
LINE / BATTERY TRANSFER | |||||
Transfer Time From Line Power to Battery Mode | 2-4 milliseconds | 2-4 milliseconds | 2-4 milliseconds | 2-4 milliseconds | 2-4 milliseconds |
Low Voltage Transfer to Battery Power | Switches to battery power as line voltage drops to 89V or lower / Resets to AC mode as line voltage increases to 94V or higher | Switches to battery power as line voltage drops to 89V or lower / Resets to AC mode as line voltage increases to 94V or higher | Switches to battery power as line voltage drops to 89V or lower / Resets to AC mode as line voltage increases to 94V or higher | Switches to battery power as line voltage drops to 75V or lower / Resets to AC mode as line voltage increases to 79V or higher | Switches to battery power as line voltage drops to 75V or lower / Resets to AC mode as line voltage increases to 79V or higher |
High Voltage Transfer to Battery Power | Switches to battery power as line voltage increases to 139V or higher / Resets to line power as line voltage drops to 135V or less | Switches to battery power as line voltage increases to 139V or higher / Resets to line power as line voltage drops to 135V or less | Switches to battery power as line voltage increases to 139V or higher / Resets to line power as line voltage drops to 135V or less | Switches to battery power as line voltage increases to 147V or higher / Resets to line power as line voltage drops to 143V or less | Switches to battery power as line voltage increases to 147V or higher / Resets to line power as line voltage drops to 143V or less |
SPECIAL FEATURES | |||||
Cold Start | Yes, inverter can be "cold started" to enable temporary AC output during a power failure | ||||
Appearance | Attractive black color scheme | ||||
CERTIFICATIONS | |||||
Certifications | Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), NOM (Mexico), Class B (Emissions) | ||||
WARRANTY | |||||
Manufacturer's Product Warranty | 2-years | 2-years | 2-years | 2-years | 2-years |
Connected Equipment Insurance | $200,000 (USA & Canada only) |
$200,000 (USA & Canada only) |
$200,000 (USA & Canada only) |
$250,000 connected equipment insurance (USA & Canada only) |
$250,000 connected equipment insurance (USA & Canada only) |
Optional Coverage | 3 Year: WEXT3-OMNI, 5 Year: WEXT5-OMNI |
3 Year: WEXT3-OMNI, 5 Year: WEXT5-OMNI |
3 Year: WEXT3-500-1500, 5 Year: WEXT5-500-1500 |
3 Year: WEXT3-500-1500, 5 Year: WEXT5-500-1500 |
3 Year: WEXT3-500-1500, 5 Year: WEXT5-500-1500 |
Manuals
Related Articles
How-To Corner
Request A Quote
Did you know that we can give you a quote for most of our products, including shipping?
You can also call us toll free 1-833-3CABLEORG (1-833-322-2536)
Questions & Answers
Do you have any questions about this product?
Let our experts and customers resolve all your doubts