Tripp Lite Commercial Grade OmniSmart UPS Systems
The Optimal Solution for Retail or Network Power Protection Applications
What's special about these uninterruptible power systems?
- Built-in Faraday-shielded isolation transformers ensure superb filtering of potentially damaging line noise.
- Equipped with AVR that allows you to continue working indefinitely through brownouts.
- For ultimate protection, all of the AC outlets on your UPS will stop damaging lightning and power surges from harming your equipment.
- Click for More Features
Part # | Description | Volts | Full Load Runtime | Dimensions | Weight | Price |
---|---|---|---|---|---|---|
TL-OMNI500ISO | OmniSmart UPS | 500 | 5 min. | 14" H x 8.5" W x 11" D | 27 lbs | Manufacturer Direct
|
TL-OMNI750ISO | OmniSmart UPS | 750 | 13 min. | 18.25" H x 13.75" W x 12" D | 40 lbs | Manufacturer Direct
|
TL-OMNI1000ISO | OmniSmart UPS | 1000 | 8 min. | 18.25" H x 13.75" W x 12" D | 40 lbs | Manufacturer Direct
|
Commercial-grade UPS systems are typically used in a climate-controlled locations where the elements are monitored to secure the highest possible performance of critical systems servers, routers, and data drives. Tripp Lite's Commercial UPS systems are ideal for POS systems such as cash registers and kiosks as well as computer labs and other climate-controlled locations. These smaller, less expensive uninterruptible power systems are designed to efficiently meet the needs of today's rapidly changing technology.
Applications:
OMNI500ISO OmniSmart UPS with built-in isolation transformer
OMNI750ISO OmniSmart UPS with built-in isolation transformer
OMNI1000ISO OmniSmart UPS with built-in isolation transformer
Estimated Runtime - Loads in Watts | ||||||||||||||||||
UPS | 20W | 40W | 60W | 80W | 100W | 120W | 140W | 160W | 180W | 200W | 260W | 300W | 340W | 400W | 460W | 500W | 600W | 700W |
HTSP-OMNI500ISO | 337 | 208 | 147 | 112 | 89 | - | - | - | - | 42 | - | 25 | - | 17 | - | 13 | 9.9 | 8 |
HTSP-OMNI750ISO | 337 | 209 | 148 | 113 | 90 | - | 63 | - | - | 42 | 30 | 25 | 21 | 17 | 14 | 13 | - | - |
HTSP-OMNI1000ISO | 93 | 56 | 38 | 29 | 22 | 14 | 11 | 11 | 11 | 9.1 | 6 | 5 | - | - | - | - | - | - |
All runtime values are in minutes
TL-OMNI500ISO | TL-OMNI750ISO | TL-OMNI1000ISO | |
SYSTEM OVERVIEW | |||
Voltage compatibility: | 120V | 120V | 120V |
---|---|---|---|
Frequency compatibility: | 60Hz | 60Hz | 60Hz |
OUTPUT | |||
Output VA: | 500 | 750 | 1000 |
Output watts: | 300 | 500 | 700 |
Line Mode Output nominal voltage: | 120V | 120V | 120V |
Battery Mode Output nominal voltage: | 115V | 115V | 115V |
Line Mode Output voltage regulation: | Sine wave line voltage 120V (-18% / +8%) | Sine wave line voltage 120V (+8%/-18%) | Sine wave line voltage 120V (-18%/+8%) |
Battery Mode Output voltage regulation: | 115V ±5% | 115V ±5% | 115V ±5% |
Line Mode Output frequency regulation: | Passes line frequency of 60Hz ±10% | Passes line frequency of 60Hz ±10% | Passes line frequency of 60Hz ±10% |
Outlet quantity/type: | 3 NEMA 5-15R | 6 NEMA 5-15R | 6 NEMA 5-15R |
INPUT | |||
Maximum input amps: | 4.8A @ 120V | 5.5A | 7.6A @ 120V |
Input connection type: | NEMA 5-15P, right-angle plug | NEMA 5-15P | NEMA 5-15P |
Input cord length: | 6' (1.8m) | 6' (1.8m) | 6' (1.8m) |
Recommended electrical service: | 15A 120V | 15A, 120V | 15A 120V |
BATTERY | |||
Full load runtime: | 5 min. (300W) | 13 min. (750VA/500W) | 8 min. (700W) |
Half load runtime: | 11 min. (150W) | 31 min. (375VA/250W) | 24 min. (350W) |
DC system voltage: | 12VDC | 36VDC | 36V |
Typical battery lifespan: | 4-6 years typical | 4-6 years (typical) | 4-6 years (typical) |
Battery recharge rate: | 2-4 hours to 90% | 2-4 hours to 90% | 2-4 hours to 90% |
Replacement battery cartridge: | RBC51 | RBC51 (3 required) | RBC53 |
VOLTAGE REGULATION | |||
Voltage regulation description: | Single boost level of brownout correction to maintain usable, computer grade output. | 2 boost levels of brownout correction and 1 voltage reduction level for over voltage correction to maintain usable, computer grade output | 2 levels of brownout correction and 1 level of over voltage correction to maintain usable, computer grade output |
Over voltage correction: | Input voltages between 128-143V are reduced by 9% | Input voltages between 128-143V are reduced by 9% | |
Brownout correction: | Input voltages between 83 and 107VAC are boosted by 14% | Input voltages between 97-107V are boosted by 10% | Input voltages between 96-107V are boosted by 10% |
Severe brownout correction: | Input voltages between 81-96V are boosted by 21% | Input voltages between 85-95V are boosted by 20% | |
LEDS ALARMS & SWITCHES | |||
Front panel LEDs: | 4 front-panel status indicator LEDs for line power, battery power, voltage regulation and battery low/replace status | 5 front-panel status indicator LEDs for line power, battery power, voltage regulation, overload and battery low/replace status | 5 diagnostic LEDs indicate AC present, on battery, voltage correction status, overload and battery low/replace status |
Alarms - assuming full load: | Audible alarm indicates power failure conditions, silence able via alarm cancel switch. Once cancelled, alarm will resume when approximately 2 minutes of battery operation remain | Audible alarm indicates power failure conditions, silence able via alarm cancel switch. Once cancelled, alarm will resume when approximately 2 min. of battery operation remain | Audible alarm indicates power failure conditions, silence able via alarm cancel push-button switch. Once cancelled, alarm will resume when approximately 2 min. of battery operation remain |
Switches: | 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions | 2 front panel-mounted push-button switches for system enable, self-test and alarm cancel functions | 2 front panel push-button switches for system enable, self-test, and alarm cancel functions |
SURGE/NOISE SUPPRESSION | |||
AC surge suppression - voltage withstand capability: | ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave | ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave | ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave |
AC surge suppression - voltage attenuation: | N-G 2000:1, L-G 240:1, L-N 100:1 | N-G 2000:1, L-G 240:1, L-N 100:1 | N-G 2000:1, L-G 240:1, L-N 100:1 |
AC surge suppression -insertion loss: | 65 db N-G from 10Khz to 100Khz, 45 to 60 db L | 65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G | 65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G |
AC suppression response time: | Instantaneous | Instantaneous | Instantaneous |
EMI/RFI AC noise suppression: | Yes | Yes | Yes |
PHYSICAL | |||
Shipping weight: | 27 lbs. (12.3 kg) | 40 lbs. (18.2 kg) | 40 lbs. (18 kg) |
Shipping Dimensions: | 14"H x 8.5"W x 11"D (35.6 x 21.6 x 27.9 cm) |
18.25"H x 13.75"W x 12"D (46.4 x 34.9 x 30.5 cm) |
18.25"H x 12"W x 13.75"D (46.4 x 30.5 x 35 cm) |
Unit weight: | 21.8 lbs. (9.9 kg) | 36.4 lbs. (16.5 kg) | 36.4 lbs. (16.38 kg) |
Unit Dimensions: | 10.75"H x 5.25"W x 7.5"D (27.3 x 13.3 x 19.1 cm) |
12.75"H x 9.25"W x 7.5"D (32.4 x 23.5 x 19.1 cm) |
12.75"H x 7.5"W x 9.25"D (32.4 x 19.05 x 23.5 cm) |
Material of construction: | PVC | PVC | PVC |
Form factors supported: | Tower | Tower | Tower |
Cooling method: | Convection | Fan | Fan |
Battery Access: | Via battery access door | Battery access door | Battery access door |
ENVIRONMENTAL | |||
Operating Temperature: | 32°F to 104°F (0°C to 40°C) | 32°F to 104°F (0°C to 40°C) | 32°F to 104°F (0°C to 40°C) |
Storage Temperature: | 5°F to 122°F (-15°C to 50°C) | 5°F to 122°F (-15°C to 50°C) | 5°F to 122°F (-15°C to 50°C) |
Relative Humidity: | 0 to 95%, non-condensing | 0 to 95%, non-condensing | 0 to 95%, non-condensing |
COMMUNICATIONS | |||
Network monitoring port: | USB | USB | USB |
Cabling included: | USB cable | USB cable | USB cable |
Software: | PowerAlert software available via free download | PowerAlert software available via free download | PowerAlert software available via free download |
WatchDog compatibility: | - | Yes with optional WATCHDOGSW | Yes, with optional WATCHDOGSW |
LINE/BATTERY TRANSFER | |||
Transfer time from line power to battery mode: | 2-4 milliseconds | 2-4 milliseconds | 2-4 milliseconds |
Low voltage transfer to battery power: | 83V (resets to line as voltage increases to 87V) | 81V (resets to line power as line voltage increases to 85V or higher) | 81V (resets to line power as voltage increases above 85V) |
High voltage transfer to battery power: | 147V (resets to line power as voltage decreases to 143V) | 143V (switches to line power as line voltage decreases to 139V or lower) | 143V (resets to line power as voltage decreases to 139V) |
SPECIAL FEATURES | |||
Cold Start: | Inverter can be "cold started" to enable temporary AC output during power failure | Inverter can be cold started to enable temporary AC output during power failure | Inverter can be cold started to enable temporary AC output during power failure |
Appearance: | Attractive all-black color scheme | Attractive all-black color scheme | Attractive all-black color scheme |
CERTIFICATIONS | |||
Certifications: | Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), Class B (Emissions) | Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), Class B (Emissions) | Tested to UL1778 (USA), CSA C22.2 No. 107.3 (Canada), Class A (Emissions), NOM (Mexico) |
WARRANTY | |||
Manufacturer's product warranty: | 2-year | 2-year | 2-year |
Connected equipment insurance (USA and Canada only): | $200,000 | $200,000 | $200,000 |
Optional warranty coverage from manufacturer: | 3-year, 5-year, next-day and on-site | 3-year, 5-year, next-day and on-site | 3-year and 5-year |
Manuals
Related Articles
How-To Corner
Request A Quote
Did you know that we can give you a quote for most of our products, including shipping?
You can also call us toll free 1-833-3CABLEORG (1-833-322-2536)
Questions & Answers
Do you have any questions about this product?
Let our experts and customers resolve all your doubts