Southwire® ShockShield® GFCI Extension Cord

Simple Extension Provides Heavy Duty Electrical Protection


14880001-6
Qty:  

What's special about this Southwire® inline GFCI Cord?

  • Provides portable GFCI protection up to 100ft for indoor or outdoor applications
  • Auto Reset models do not need to be manually activated after a power outage, to give you shorter down times
  • Locking models available for harsher applications
  • Available in several styles including right angle plugs, tri-cord, and inline GFCI cords
  • Click for More Features

Distributing electricity can get tricky around the workplace, jobsite, or lawn, garden, or patio. Southwire® ShockShield® GFCI extension cords make the process easy and extremely safe. In the event the outdoor GFCI extension cord detects a ground fault, it will shut off, protecting you from electrocution or shock and preventing costly damage to equipment. It's even rain proof for marine/water based applications!

Southwire® ShockShield® GFCI RIGHT ANGLE Cord Set
Part # Voltage Gauge Length Weight Price
14880001-6 120V/15A 14/3 AWG 9" 0.3 lb
Qty:  
14880024-3 120V/15A 14/3 AWG 6 ft 0.8 lb
Qty:  
Southwire® ShockShield® GFCI Protected Right Angle Tri-Cord Plug
Part # Receptacle Voltage Gauge Length Weight Price
14880023-6 - 120V/15A n/a 2 ft 1 lb
Qty:  
14880004-6 - 120V/15A n/a 6 ft 1.6 lbs
Qty:  
14880118-2 - 120V/15A n/a 25 ft 4.26 lbs
Qty:  
14880119-1 - 120V/15A n/a 50 ft 8.4 lbs
Qty:  
14880120-1 - 120V/15A n/a 99 ft 12 lbs
Qty:  
14880226-6 Lighted 120V/15A n/a 2 ft 1 lb
Qty:  
Southwire® ShockShield® GFCI IN-LINE Cord Sets
Part # Receptacle Voltage Gauge Length Weight Price
26020002-6 - 120V/15A 14/3 AWG 2 ft 0.74 lb
Qty:  
26020124-2 - 120V/15A 14/3 AWG 25 ft 2.33 lbs
Qty:  
26020050-1 - 120V/15A 14/3 AWG 50 ft 4.28 lbs
Qty:  
26020011-6 - 120V/15A 12/3 AWG 2 ft 0.54 lb
Qty:  
26020150-1 - 120V/15A 12/3 AWG 50 ft 8.23 lbs
Qty:  
25080025-2 - 120V/20A 12/3 AWG 25 ft 4.31 lbs
Qty:  
25090001-6 - 240V/15A 14/3 AWG 2 ft 0.74 lb
Qty:  
26000011-6 - 240V/20A 12/3 AWG 2 ft 0.74 lb
Qty:  
Southwire® ShockShield® GFCI Protected IN-LINE Tri-Cord Plug
Part # Receptacle Voltage Gauge Length Weight Price
26020008-6 - 120V/15A n/a 2 ft 1.25 lbs
Qty:  
26020148-1 - 120V/15A n/a 50 ft 8.35 lbs
Qty:  
  • Up to 12 AWG cables for durability
  • Typical applications include:
    • Construction Sites
    • Portable Electric Power Tools
    • Saws and Drills
    • Multiple Tools Use
    • Basements
    • Bathrooms
    • Laundry Rooms
    • Kitchens
    • Any place where electricity is used around water
  • TRC-14880 dimensions (PDF) PDF
  • TRC-14880 Tri Cord Plug dimensions (PDF) PDF
  • TRC-26020, TRC-25080, TRC-25090, TRC-26000 dimensions (PDF) PDF
  • TRC-26020 Tri Cord Plug dimensions (PDF) PDF
  • TRC-44700, TRC 44720 dimensions (PDF) PDF
  • NEMA Plug and Receptacle Configurations (PDF) PDF
  •  

    Technical Data Right Angle Cord Sets In-Line Cord Sets In-Line Cords
    with Locking Plug
    Protected Tri-Cord
    Ground Neutral 4 Ohms typical 4 Ohms typical 4 Ohms typical 4 Ohms typical
    Trip response time for ground and grounded neutral trip fault less than 25mS fault less than 25mS fault less than 25mS fault less than 25mS
    Voltage surge withstand 3kv ringwave test and 4kv/2kA surge immunity test 3kv ringwave test and 4kv/2kA surge immunity test 3kv ringwave test and 4kv/2kA surge immunity test 3kv ringwave test and 4kv/2kA surge immunity test
    Radio frequency noise susceptibility operates within normal limits with 0.5 volts injected on power line 150kHz-230mHz operates within normal limits with 0.5 volts injected on power line 150kHz-230mHz operates within normal limits with 0.5 volts injected on power line 150kHz-230mHz operates within normal limits with 0.5 volts injected on power line 150kHz-230mHz
    Frequency 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz 50 / 60 Hz
    Endurance 3,000 operations minimum 3,000 operations minimum 3,000 operations minimum 3,000 operations minimum
    Overload Current six times rated current six times rated current six times rated current six times rated current
    Operating temperature range -35°C to 66°C -35°C to 66°C -35°C to 66°C -35°C to 66°C
    Effect of 10 Amp turn DC Shock on ground fault trip 5% maximum trip
    level variation
    5% maximum trip
    level variation
    5% maximum trip
    level variation
    5% maximum trip
    level variation
    Insulation voltage 1500VRMS - 1Min. 1500VRMS - 1Min. 1500VRMS - 1Min. 1500VRMS - 1Min.
    Power On indication mechanical indicator lighted indicator mechanical indicator, red stripe on reset lighted indicator
    Related Articles




     

    How-To Corner



     

    Request A Quote

    Did you know that we can give you a quote for most of our products, including shipping?

    You can also call us toll free 1-833-3CABLEORG (1-833-322-2536)

    Questions & Answers

    Do you have any questions about this product?
    Let our experts and customers resolve all your doubts