Home > Networking > Media Converters > 10/100T to 100FX Industrial DIN-Rail Mount Hardened Converter
10/100 to 100FX WDM DIN-Rail Mount Hardened Media Converters
Built To Last Ethernet Media Converter
|
Click image for larger view |
What's special about these Hardened Ethernet switches?
Signamax's Industrial Hardened Media Converter is a cost effective solution for expanding or extending an existing Ethernet/Fast Ethernet network. It is a small, economical and durable media conversion solution that provides network administrators the ability to migrate or upgrade twisted pair based networks to fiber optic based networks. |
- Plug-and-play, doesn’t required complex user setup however also have the manual setting features necessary to adjust to unusual operating conditions
- Meets NEMA TS1 Environmental Requirements for Traffic Control Equipment
- Meets EC61000-6-2 EMC Generic Standard Immunity for Industrial Environment
- RJ-45 Port Auto-Negotiates 10/100Mbps & Full/Half-Duplex Mode, with Auto-MDIX
- 100FX Port Available with Multimode, Singlemode, and WDM Singlemode
- DIP Switch Configuration for Link Fault Signaling Link Down Alarm, Plus Speed/Duplex Mode
- Non-Blocking Store-and-Forward Mechanism for Full Wire-Speed Performance
- Supports 2K MAC Addresses
- Broadcast Storm Filtering
- Back-Pressure and IEEE 802.3x Compliant Flow Control
- Alarms for Power Failure and Port Link Failure via Relay Output
- Redundant 24V DC Terminal Block Power Inputs
- Supports DIN-rail or Panel Mount Installations
- Lifetime manufacturer warranty
APPLICABLE STANDARDS |
|
IEEE 802.3 10BaseT |
|
FIXED PORTS |
|
1 twisted-pair port meeting IEEE 802.3 10BaseT & IEEE 802.3u 100BaseTX standard
specifications, Auto MDI/MDI-X and Auto-Negotiation Function supported (all models)
PLUS 1 100Base FX port meeting IEEE 802.3u 100BaseFX standard specifications with WDM A SC/SM simplex, 20 km span (Models 065-1876ATB) OR 1 100Base FX port meeting IEEE 802.3u 100BaseFX standard specifications with WDM B SC/SM simplex, 20 km span (Models 065-1876BTB) |
|
TWISTED-PAIR CABLE REQUIREMENTS |
|
Category 5 or better cable, 100 meters maximum distance for 100BaseTX, Category 3 or better cable, 100 meters
maximum distance for 10BaseT
|
|
LED STATUS INDICATORS |
|
Per Unit: |
Power1 (Green), Power2 (Green). Fault, LFS |
Per Port: |
10/100 port: 100 Mbps Speed, Link/Activity,
FDX/COL 100FX port - Link/Activity, FDX/COL |
PERFORMANCE |
|
Latency: |
< 4.2 µs (LIFO) |
Throughput @ 100Base: |
148,810 pps (64-byte packets) |
SWITCH ARCHITECTURE |
|
Store and Forward |
|
FIBER INTERFACE, SINGLEMODE PN 065-1876ATB |
|
Type: |
MQW Laser |
Transmit Wavelength: |
1310 nm nominal (1260 nm maximum, 1360 nm minimum) |
Receive Wavelength: |
1550 nm nominal (1480 nm maximum, 1600 nm minimum) |
Maximum Output Power: |
- 8.0 dBm |
Minimum Output Power: |
- 14.0 dBm |
Sensitivity: |
-33.0 dBm |
Maximum Input Power: |
- 3.0 dBm |
Link Power Budget: |
19.0 dB |
FIBER INTERFACE, SINGLEMODE PN 065-1876BTB |
|
Type: |
|
Transmit Wavelength: |
1550 nm nominal (1480 nm maximum, 1580 nm minimum) |
Receive Wavelength: |
1310 nm nominal (1260 nm maximum, 1360 nm minimum) |
Maximum Output Power: |
- 8.0 dBm |
Minimum Output Power: |
- 14.0 dBm |
Sensitivity: |
-33.0 dBm |
Maximum Input Power: |
- 3.0 dBm |
Link Power Budget: |
19.0 dB |
POWER INPUT REQUIREMENTS |
|
Redundant 12 to 48 Volts DC Terminal Block |
|
PHYSICAL CHARACTERISTICS |
|
Dimensions: |
1.97 in. x 5.35 in. x 4.33 in., W x H x D (50 mm x 136 mm x 110 mm) |
Housing: |
IP-30 protection, metal case |
Weight: |
1.76 lb (0.8 kg.) |
CERTIFICATIONS |
|
NEMA TS1/2 Environmental requirements for traffic control equipment |
|
ISO: |
Manufactured in an ISO9001 facility |
Environmental Test Compliance: |
Vibration Resistance (IEC 60068-2-6): 5G@150Hz;
Criterion 3 Operation/Storage/Transport Shock (IEC 60068-2-27): 25G @ 11ms (Half-Sine Shock Pulse; Operation) 50G @ 11ms (Half-Sine Shock Pulse: Storage/Transport) Free Fall (IEC 60068-2-32): Free Fall: 1M (3.281 ft.) |
ESD Standards (IEC 61000-4-2): |
Enclosure Contact: +/- 4kV; Criteria B Enclosure Air: +/- 8kV; Criteria B |
Radiated FRI Standards (IEC 61000-4-3): |
Enclosure Ports: +/- 4kV@2.5kHz; Criteria B |
Burst Standards (IEC 61000-4-4): |
Enclosure Ports: 10V/m, 80 to 1000MHz; Criteria A D.C. Power Ports: +/- 4kV; Criteria B A.C. Power Ports: +/- 4kV; Criteria B |
Surge Standards (IEC 61000-4-5): |
Signal Ports: +/- 1kV Line-to-earth; Criteria B D.C. Power Ports: +/- 0.5kV Line-to-earth; Criteria B A.C. Power Ports: +/- 2kV; Line-to-earth; Criteria B |
Induced RFI Standards (IEC 61000-4-6): |
Signal Ports: 10v@ 0.15 - 80 MHz; Criteria A DC Power Ports: 10v@ 0.15 - 80 MHz; Criteria A AC Power Ports: 10v@ 0.15 - 80 MHz; Criteria A Earth Ground Ports: 10v@ 0.15 - 80 MHz; Criteria A |
Magnetic Field Standards (IEC 61000-4-8): |
Enclosure Ports: 30A/m@ 50, 60Hz; Criteria A |
Voltage Dip Standards (IEC 61000-4-11): |
AC Power Ports: 30% Reduction for 0.5 period; Criteria B |
ENVIRONMENT |
|
Operating Temperature: |
-40°F to 176°F (-40°C to 80°C) |
Storage Temperature: |
-50°F to 200°F (-45°C to 93°C) |
Operating Humidity: |
10 to 95% (non-condensing) |
INSTALLATION |
|
DIN Rail Kit, or wall mounting ears for 3-way installation |
|
EMISSIONS |
|
| Part 15 Class A |
|
CE: |
EN55022 (CISR22 Class A), EN55024 (CISPR24 Class A), CE EN-6100-4-4, CE EN6100-4-5, CE EN6100-4-6 |
SAFETY |
|
UL 60950, EN 60950, IEC 60950, IEC 61000-6-2 |
|
The following table lists the pinout of 10/100BaseT/TX ports:
PIN |
REGULAR PORTS |
UPLINK PORT |
1 |
Input Receive Data + |
Output Transmit Data + |
2 |
Input Receive Data - |
Output Transmit Data - |
3 |
Output Transmit Data + |
Input Receive Data + |
4 |
NC |
NC |
5 |
NC |
NC |
6 |
Output Transmit Data - |
Input Receive Data - |
7 |
NC |
NC |
8 |
NC |
NC |
10/100T to 100FX Industrial DIN-Rail Mount Hardened Converter
| PART # | DESCRIPTION | DIMENSION | WEIGHT | PRICE |
| SX-065-1876ATB | WDM A Simplex SC/SM 20 km; Tx=1310 nm, Rx=1550 nm – 24V DC Terminal Block | 1.97" W. x 5.35" Hx 4.33" D (50 mm x 136 mm x 110 mm) |
1.76 lb (0.8 kg.) | $972.00![]() |
| SX-065-1876BTB | WDM B Simplex SC/SM 20 km; Tx=1550 nm, Rx=1310 nm – 24V DC Terminal Block | 1.97" W. x 5.35" Hx 4.33" D (50 mm x 136 mm x 110 mm) |
1.76 lb (0.8 kg.) | $1,080.00![]() |
MANUALS -
| EU EMC Generic Immunity Standards |
||||
| Basic Standards | EN 50082-2: 1995 | EN 61000-6-2: 1999 | EN 50082-1: 1997 | Performance Criteria |
EN 61000-4-2/ |
±4-kV contact discharge |
±4-kV contact discharge |
±4-kV contact discharge |
B |
EN 61000-4-3 |
80 to 1,000 MHz, 10 V/m 80% AM w/1-kHz sine wave |
80 to 87 MHz, 10 V/m |
80 to 1,000 MHz 80% AM w/1-kHz sine wave |
A |
EN 61000-4-4/ |
±1-kV signal ports |
±1-kV signal ports |
±0.5-kV signal ports |
B |
EN 61000-4-5/ |
N/A |
Signal: ±1-kV line-to-earth |
(Signal port testing not required) |
B |
EN 61000-4-6/ |
0.15 to 80 MHz, 10 Vrms 80% AM w/1-kHz sine wave |
0.15 to 47 MHz, 10 Vrms |
0.15 to 80 MHz, 3 Vrms 80% AM w/1-kHz sine wave |
A |
EN 61000-4-8/ |
50 Hz, 30 A/m |
50 Hz or 60 Hz, 30 A/m |
50 Hz, 3 A/m |
A |
EN 61000-4-11/ |
N/A |
30% reduction; 10 ms |
30% reduction; 10 ms |
B C C |
Installation
When working with electrical devices, place the equipment where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. The location you choose should meet the following requirements:
- The temperature should be between -40° to 165° F (-40° to +74° C)
- Relative humidity should be less than 95 percent, non-condensing
- Surrounding electrical devices should not exceed the electromagnetic field (RFC) standards for IEC 801-3, Level 2 (3V/M) field strength
- Make sure that the equipment receives adequate ventilation. Do not block the ventilation holes of the equipment
- The power outlet should be within 6 feet (1.8 meters) of the product
CATALOG - PDF
For your convenience, we have made our brochure and catalogs available online in PDF format. Downloading the PDF catalog will take you no more than 5 minutes, so you won't have to wait days for the print catalog. PDF catalogs include links to our products: just click on the hyperlinked product headings, and you'll be directed right to our website.
Office
PDF Catalog 2 MB
Utilities & Energy
PDF Catalog 3.7 MB
Datacom/Telecom
PDF Catalog 5.7 MB






View Cart