Home > Fire Protection > Water Based Caulks > Fire Barrier CP 25WB+Caulk
Click images to enlarge
|
What's special about this caulk?
- Water Base: Easy clean up, no special handling, routine disposal
- Intumescent: Expands when heated to seal around items consumed by fire
Endothermic: Absorbs heat energy, releases chemically bound water
- Thixotropic: Will not sag or run in overhead or vertical applications
- Click here for more features
3M™ Fire Barrier CP 25WB+ Caulk is a premium elastomeric latex caulk designed for use as a one-part fire, smoke, noxious gas and water sealant. In addition, the unique intumescent property of this material (expands when heated) means that as cable or pipe insulation is consumed by fire, CP 25WB+ Caulk expands to maintain the penetration seal.
|
- Halogen-free
- Fast dry : Tack-free in approximately 10-15 minutes
- Paintable (Best results obtained after 72 hour cure)
- Minimal shrinkage
- Brown color
- Water seal: Seals against inadvertent water spills in the unexpanded state
- High caulk rate: 1000 g/min. with in. nozzle
- Point contact allowed
- Continuous Operating Temperature not to exceed 120°F (48°C)
- Made in the USA
CP 25WB+ Caulk features superior adhesion strength, caulk rate and no sag application with expanded UL Classified fire protection systems plus a halogen-free formula.
3M Fire Barrier CP 25WB+ Caulk can be installed with a standard caulking gun, pneumatic pumping equipment or it can be easily applied with a putty knife or trowel. CP 25WB+ Caulk will bond to concrete, metals, wood, plastic and cable jacketing. No mixing is required.
Applications
Use to seal construction openings, blank openings and penetrating items against the passage of flame, noxious gas, smoke and water. Restores fire rated construction to original integrity. Also for use with 3M Brand Fire Barrier FS195+ Wrap/Strip and CS-195+ Composite Sheet.

FILL, VOID OR CAVITY MATERIALS FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS.
SEE UL DIRECTORY OF PRODUCTS CERTIFIED FOR CANADA AND UL FIRE RESISTANCE DIRECTORY 50L6.
Product
The firestopping caulk shall be a one-part, intumescent, latex elastomer. The caulk shall be capable of expanding a minimum of 3 times at 1000°F. The material shall be thixotropic and be applicable to overhead, vertical and horizontal firestops. The caulk shall be listed by independent test agencies such as UL or FM and be tested to, and pass the criteria of, ASTM E 814 Fire Test, tested under positive pressure. It shall comply with the requirements of the NEC (NFPA-70), BOCA, ICBO, SBCCI and NFPA Code #101.
| Typically Specified Divisions |
Division 7
07270 |
Thermal and Moisture Protection Firestopping |
Division 13
13900 |
Special Construction Fire Suppression and Supervisory Systems |
Division 15
15250
15300 |
Mechanical
Mechanical Insulation Fire Protection |
Division 16 Electrical
16050 |
Electrical
Basic Electrical Materials and Methods |
| Performance |
| |
Unit |
Value |
Tack Free Time
(ASTM C679-87) |
Minutes at 72°F (22°C) |
10-15 |
Expansion at 662°F (350°C) |
X |
2.0-3.0 |
Color |
– |
Reddish Brown |
Density |
Lb./gal. (Kg/l) |
11.2 (1,35) |
Adhesion |
All construction substrates |
Very Good |
Application |
Method |
Caulk guns, trowel, spatula pressurized pumps |
Durometer (hardness) |
Shore A |
70 |
ASTM E 84
Flame Spread
Smoke Development
|
–
– |
5
0 |
Solids |
Percent (%) by weight |
79 |
VOC |
Percent (%) by weight |
0 |
Odor |
– |
Pleasant, non-irritating |
Flow Rate
1/4 in. (6,35 mm)
nozzle at 50 psi |
Grams/min. |
1000 |
Boeing Flow
(Sag Characteristics) |
Inches |
0 |
Firestopping Properties
Meets the criteria of ASTM E 814 Fire Test, tested under positive pressure.
Consult current UL Fire Resistance Directory for systems listed under 3M Product CP 25WB+ Caulk.
Firestopping Code Requirements
ICBO Uniform
Building Code (1997 Edition) |
SBCCI Standard
Building Code (1997 Edition) |
BOCA Basic/National Building Code(1996 Edition) |
NFPA Life Safety Code 101 (1997 Edition) |
702
DEFINITIONS
706
CONSTRUCTION JOINTS
708
WOOD FRAME
CONSTRUCTION
FIREBLOCKING
709
WALL & PARTITION
PENETRATION
PROTECTION
709.3.2.2
CURTAIN WALL GAP
710
FLOOR/CEILING OR
ROOF/CEILING
PENETRATION
PROTECTION
711.3
SHAFT ALTERNATIVE
714
THROUGH-PENETRATION
FIRESTOPS F&T
REQUIREMENTS
UBC STANDARD 7-1
EQUIVALENT TO
ASTM E 119
UBC STANDARD 7-5
EQUIVALENT TO
ASTM E 814 |
104.2.4
PLANS MUST SHOW HOW
INTEGRITY IS
MAINTAINED FOR
ASSEMBLIES PENETRATED
202
DEFINITIONS
705.3
WOOD FRAME
CONSTRUCTION
FIREBLOCKING
705.3.1.5
CURTAIN WALL GAP
705.4 (GENERAL)
PENETRATIONS OF FIRE
RATED ASSEMBLIES
705.5 (WALLS)
705.6 (FLOORS)
705.7
FIRE RESISTANT JOINT
SYSTEMS |
702.0
REVISED AND
EXPANDED DEFINITIONS
FOR PENETRATIONS
AND JOINTS
703.1
CONSTRUCTION
DOCUMENTS SHALL
INDICATE DETAILS AND
MATERIALS FOR
PROVIDING RATINGS AT
JOINTS AND
PENETRATIONS
703.1.1
PENETRATIONS AND
JOINTS SHALL NOT BE
CONCEALED FROM
VIEW BEFORE
INSPECTION
703.2
BUILDINGS FOR MORE
THAN TWO STORIES
SHALL INDICATE
ALL PENETRATIONS
704.1.1
SUFFICIENT DATA
SHALL BE AVAILABLE
TO JUSTIFY UNTESTED
MATERIALS USED FOR
RESTORATION OF FIRE
RATINGS
707.0
FIRE WALLS AND
PARTY WALLS
707.10
PENETRATIONS -
REFERS TO 714
707.8
JOINTS - REFERS TO
709.7
709.0
FIRE SEPARATION
ASSEMBLIES |
709.6
PENETRATIONS - REFER
TO 714
709.7
JOINTS
711.0
FIRE PARTITIONS
711.6
PENETRATIONS - REFERS
TO 714
711.7
JOINTS - REFER TO 709.7
713.0
FLOOR/CEILING AND
ROOF/CEILING
ASSEMBLIES
713.2
CURTAIN WALL GAP
713.4
PENETRATIONS - REFERS
TO 714
713.5
JOINTS - REFERS TO
709.7
714.0
PENETRATIONS - ALL
REQUIREMENTS
(GENERAL)
714.1 THROUGH 714.1.6.2
WALL ASSEMBLIES
714.2 THROUGH 714.2.6.5 FLOOR/CEILING AND
ROOF/CEILING
ASSEMBLIES
714.3 THROUGH 714.3.2
NONRATED ASSEMBLIES
721.0
FIREBLOCKING AND
DRAFTSTOPPING |
6-2.3.2.4
PENETRATIONS AND
MISC. OPENINGS&FIRE BARRIERS
6.2.4.2, EXCEPTION
5 OPENINGS (EXPANSION
OR SEISMIC JOINTS) IN
FLOORS
APPENDIX
A-6-2.4.2
6-3.6.1
PENETRATIONS AND
MISC. OPENINGS
IN FLOORS AND SMOKE
BARRIERS
NFPA #221
FIRE WALLS AND |
NFPA
Code 70 NEC
National
Electric Code
300-21 FIRESTOPPING
|
CABO
One and Two
Family Dwelling
Code
(1995 Edition)
602.7
FIRESTOPPING
(FIREBLOCKING IN OTHER
MODEL CODES) |

FILL, VOID OR CAVITY MATERIALS FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS.
SEE UL DIRECTORY OF PRODUCTS CERTIFIED FOR CANADA AND UL FIRE RESISTANCE DIRECTORY 50L6. |
Please Note: There is a 5 Day Lead Time on orders for Pails.
| Part # |
Package Size |
Description |
Price |
| FP-3M-CP25WB-T |
10.1 oz. Tube |
Lightweight easy to handle. Perfect for smaller jobs. |
$12.25 |
| FP-3M-CP25WB-P |
5 gallon Pail |
Great for bulk loading on large jobs. The most cost-effective way to caulk large areas. |
$405.84 |
Shown are examples of approved applications of CP 25WB+ Caulk. Additional drawings and details are available through your Authorized 3M Fire Protection Products Distributor.
Installation Notes:
- Metal Pipe/Conduit applications through nominal 12 in. (304,8 mm) outside diameter
- Installed depth of CP 25WB+ Caulk depends on annular space.
- When the annular space is less than 1-1/4 in. (31,8 mm), a 1/2 in. (12,7 mm) minimum depth of CP 25WB+ Caulk is required.
- When the annular space is greater than 1-1/4 in. (31,8 mm), a 1 in. (25,4 mm) minimum depth of CP 25WB+ Caulk is required.
- Common building materials, such as backer rod may be used for metal pipe applications.
- Metal Pipe applications larger than nominal 12 in. (304,8 mm) outside diameter.
- All cases require a 1 in. (25,4mm) minimum depth of CP 25WB+ Caulk.
- Insulated Cable Applications.
- All cases require a 1 in. (25,4mm) minimum depth of CP 25WB+ Caulk.
- All cases require mineral wool (safing) for packing.
- Fiberglass Insulated Pipe Applications.
- 1 in. (25,4 mm) of fiberglass insulation on up to a nominal 12 in. (304,8 mm) of metal pipe may be firestopped with a 1 in. (25,4 mm) depth of CP 25WB+ Caulk.
- 1 in. (25,4 mm) depth of mineral wool packing required
Maintenance
The CP 25WB+ Caulk is stable under normal storage conditions and has a one year shelf life. Normal stock and stock rotation are recommended.
Recommended Store between 40°F (4°C)-90°F (32°C) for maximum shelf life. Keep from freezing. |


 |
Warranty and Limited Remedy
This product will be free from defects in material and manufacture for a period of ninety (90) days from date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
User is responsible for determining whether the 3M product is fit for a particular purpose and suitable for user’s method of application. If this 3M product is proved to be defective within the warranty period stated above, your exclusive remedy and 3M’s sole obligation shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product.
Limitation of Liability
Except where prohibited by law, 3M will not be liable for any loss or damage arising from the use of this 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability.
|
RELATED ARTICLES -
VIEW OUR GLOSSARY
CATALOG - PDF
For your convenience, we have made our brochure and catalogs available online in PDF format. Downloading the PDF catalog will take you no more than 5 minutes, so you won't have to wait days for the print catalog. PDF catalogs include links to our products: just click on the hyperlinked product headings, and you'll be directed right to our website.
Office PDF Catalog 2 MB
Automotive PDF Catalog 2.6 MB
Aerospace/Aircraft PDF Catalog 2 MB
Utilities & Energy PDF Catalog 3.7 MB
Datacom/Telecom PDF Catalog 5.7 MB
Can we improve something on this page?
Can this page be improved? Is the information complete and easy to understand? We are always looking to improve our website, so please feel free to give us your comments, suggestions, or questions. Thanks for helping us serve you better!
|
|